ELE05-02663
| Final | 8/18/2005 | 8/18/2005 | 8/18/2005 4:49:14 PM | P | PASS |
|
|
clyde ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final
|
ELE05-02580
| Final | 8/18/2005 | 8/18/2005 | 8/18/2005 4:48:20 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 8/18/2005 at 7:37:21 AM. Contact: ###-####. ok to final
|
ELE05-01699
| Final | 8/18/2005 | 8/18/2005 | 8/18/2005 3:01:23 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 8/18/2005 at 5:52:56 AM. Contact: ###-####. corrections made, ok to final
|
ELE05-01831
| Final | 8/18/2005 | 8/18/2005 | 8/18/2005 3:00:43 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 8/18/2005 at 8:36:13 AM. Contact: ###-####. ok to final
|
ELE05-02452
| Electrical Rough-In | 8/18/2005 | 8/18/2005 | 8/18/2005 2:32:05 PM | P | PASS |
|
|
trench cover inspection please////warren; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to cover u/g up to panel from utility
|
ELE05-03031
| Rough-In Permanent Service | 8/18/2005 | 8/18/2005 | 8/18/2005 12:55:09 PM | P | FAIL |
|
|
tom ###-#### called contr, left corr notice, left do not cover sign, BCC address shall be posted, job id shall be posted, 312.5 abrasion protection shall be provided for gec, 300.4(D) nm cable shall be 1 1/4" from edge of framing member,110.12(A) unused openings in box shall be closed, 314.16 box fill shall not be exceeded
|
ELE05-03027
| Temporary Service | 8/17/2005 | 8/18/2005 | 8/18/2005 10:26:54 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/17/2005 at 3:20:01 PM. Contact: ###-####. t/s u/g n ok
|
ELE05-03028
| Conference | 8/17/2005 | 8/18/2005 | 8/18/2005 10:26:28 AM | A | DONE |
|
|
###-#### patrick talked about ckt extension for fountain and u/g to post. Also about changing garage door opener recpt.
|
ELE05-01901
| Final | 8/17/2005 | 8/18/2005 | 8/18/2005 9:52:14 AM | A | PASS |
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called contr, left message to add words to panel schedule and to check reset on jacuzzi breaker. ok to final
|
ELE05-03010
| Final | 8/17/2005 | 8/18/2005 | 8/18/2005 9:24:10 AM | A | FAIL |
|
|
for hot tub-- ###-####- john --- called contr, told owner BCC ord 4-05-33(A)(B) equip shall be listed, NEC 110.2 equip shall be acceptable only if approved
|
ELE05-02086
| Rough-In Permanent Service | 8/17/2005 | 8/18/2005 | 8/18/2005 8:39:43 AM | A | CANC |
|
|
MORGAN PERMANENT SERVICE AND UNDERGROUND; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy see ri
|
ELE05-01481
| Final | 8/18/2005 | 8/18/2005 | 8/18/2005 8:35:06 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/18/2005 at 7:12:08 AM. Contact: ###-####. called contr, left survey, 422.16(B)(2) disposal cord shall be less than 36", 210.8(A)(7) recpt by sink in laundry shall be gfci
|
ELE05-02086
| Electrical Rough-In | 8/18/2005 | 8/18/2005 | 8/18/2005 12:00:00 AM | A | FAIL |
|
|
MORGAN PERMANENT SERVICE AND UNDERGROUND; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy told contr to dig up and expose u/g to prove depth
|