Inspections for the day of: Tuesday, August 18, 2015.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02537 Electrical Rough-In8/18/20158/18/20158/18/2015 2:53:51 PMPPASS
I wont be there in the morning. It is a PV array. Panels are arriving today and the rest is done. Later in the afternoon the job will be finished. Phone #: ###-#### Inspection requested via web by George Stanton ri ok
ELE15-02569 Rough-In Permanent Service8/18/20158/18/20158/18/2015 2:47:06 PMAPASS
call dene with any questions
thank you Phone #: ###-#### Inspection requested via web by kim grundhauser called about wrong posting of address on house, contractor checked and said they would correct adress posting, ri ok, p/s u/g n ok
ELE15-02022 Final8/18/20158/18/20158/18/2015 2:12:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack ok final
ELE15-00003 Final8/14/20158/18/20158/18/2015 12:59:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Tyler Bowen ok final
ELE15-01708 Final8/17/20158/18/20158/18/2015 10:02:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn ok final
ELE15-02585 Rough-In Permanent Service8/17/20158/18/20158/18/2015 9:59:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn ri ok p/s u/g n ok
ELE15-01096 Final8/17/20158/18/20158/18/2015 9:52:43 AMAPART
Dan Hommel Phone #: ###-#### Inspection requested via web by Kerri Hamilton called, ok except shall install riser strap, intersystem grounding bar, then recall for final
ELE15-02577 Permanent Service8/17/20158/18/20158/18/2015 8:57:23 AMAPASS
Lockbox 1967, if you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan p/s u/g rec ok
ELE15-02577 Final8/17/20158/18/20158/18/2015 8:34:32 AMACANC
Lockbox 1967, if you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan see ri
ELE15-02577 Electrical Rough-In8/18/20158/18/20158/18/2015 8:34:13 AMAPASS
Lockbox 1967, if you have any questions, please call Jake ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan ri ok master bedroom only
ELE15-02496 Rough-In Permanent Service8/18/20158/18/20158/18/2015 8:10:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok