ELE13-02842
| ELE-Aging Inspection | 8/18/2017 | 8/18/2017 | 8/18/2017 1:48:18 PM | | DONE |
|
|
Neil will look into it and call for final
|
ELE17-02662
| Electrical Rough-In | 8/18/2017 | 8/18/2017 | 8/18/2017 1:45:26 PM | P | PASS |
|
|
contact is Dan, Underground in warehouse area Phone #: ###-#### Inspection requested via web by Lori Stout Underground in warehouse only ok to cover
|
ELE17-02523
| Electrical Rough-In | 8/18/2017 | 8/18/2017 | 8/18/2017 1:44:50 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by steve sellers Garage only ok to cover
|
ELE17-02156
| Final | 8/17/2017 | 8/18/2017 | 8/18/2017 11:20:46 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake Floor heat only final ok
|
ELE17-00341
| Final | 8/17/2017 | 8/18/2017 | 8/18/2017 11:20:10 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wake 210.52 A 2 (1) Fixed panels shall count as wall space. ( need recep right side of back slider fixed panel and right side of Front room fixed panel. 410.16. Recessed lighting in cloths closet shall have enclosed lamp.(laundry room closet. 210.70 A 3. Equipment rooms shall have lighting outlet.(Garage furnace room) 406.6 Receps and switches shall have cover plates installed. 110.3 B Listed equipment shall be installed per manufacturers specs.( Garage 3way locked out)
|
ELE17-02693
| Conference | 8/17/2017 | 8/18/2017 | 8/18/2017 9:38:43 AM | A | PASS |
|
|
Tim Phone #: ###-#### Talked about Grounding requirments, Sub panel ground seperation and need to update Range and Dryer circuits if 3 wire.
|
ELE17-00828
| Final | 8/17/2017 | 8/18/2017 | 8/18/2017 8:33:03 AM | A | PASS |
|
|
Remaining final for downstairs apts at building 511. Meet at Primary Office. Contact here is either Todd or Rick. Phone #: ###-#### Inspection requested via web by Todd Sellman Final ok
|
MIS17-00263
| ELE-Conference | 8/17/2017 | 8/18/2017 | 8/17/2017 10:52:16 AM | A | DONE |
|
|
building in back yard with no permits-neighbor says it''s over 200 sq ft not meeting setbacks-also doing electrical work-if have questions call neighor at ###-#### Jennifer Spoke with Jennifer. Informed her no ELE permit was needed as the lights were Low voltage plug in. Let her know there was no violation. Could be a planning and zoning issue.
|