Inspections for the day of: Friday, August 18, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-03710 Final8/17/20178/18/20178/18/2017 2:40:24 PMPPASS
PLEASE CALL OUR LEAD INSTALLER DAKODA WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC17-03714 Final8/18/20178/18/20178/18/2017 2:16:49 PMPPASS
early pm please call Josh ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC17-03712 Final8/18/20178/18/20178/18/2017 1:57:09 PMPPASS
early pm please call Tanner ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC17-03610 Final8/16/20178/18/20178/18/2017 1:49:06 PMPFAIL
Anytime after 11 please call home owner when you are on your way Phone #: ###-#### Inspection requested via web by Kristin Dolan- need uv protction on line set outside- need right size fuses in disconnect at A/C- need 24" wide access platform installed for access to furnace- 2nd drain needs to be ran within 6" of garage floor- need armor flex on copper in attic and rips fixed- gas shut off needs to be accessible since furnace moved to new location
MEC17-02976 Final8/14/20178/18/20178/18/2017 1:25:05 PMPPASS
Please Call Samantha 30 minutes prior to arrival and she will meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC17-00096 Mec-Aging Inspection8/18/20178/18/20178/18/2017 11:29:04 AM PEND
contractor looking into this per phone call
MEC17-02942 Rough-in8/17/20178/18/20178/18/2017 11:10:00 AMAPASS
Field Super; Jason Shipp Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-02008 Final8/17/20178/18/20178/18/2017 10:38:33 AMAPASS
mechanical fireplace final inspection Phone #: ###-#### Inspection requested via web by Dan Otero
MEC17-02162 Final8/17/20178/18/20178/18/2017 10:22:52 AMAPART
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- need to insulate filter box R/A on furnace
MEC17-03417 Final8/15/20178/18/20178/18/2017 9:44:16 AMAPASS
if possible can you please be there at 9am. we will be there at 8:30 am to set up for pressure test. Thanks! Phone #: ###-#### Inspection requested via web by Marisa Hone
MEC17-03417 Pressure Test8/15/20178/18/20178/18/2017 9:34:15 AMAPASS
if possible can you please be there at 9am. we will be there at 8:30 am to set up for pressure test. Thanks! Phone #: ###-#### Inspection requested via web by Marisa Hone- 5lb flue pass
MEC17-03418 Conference8/17/20178/18/20178/18/2017 9:12:02 AMAFAIL
WITNESS DUCT BLAST 830 AM Phone #: ###-#### Inspection requested via web by dannyel chaloupka- duct blast fail- 189 cfm loss- 69 max
MEC17-02726 Conference8/17/20178/18/20178/18/2017 8:39:15 AMAPASS
WI DUCT BLAST 8 AM Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 83 cfm loss
MEC17-02942 Rough-in8/17/20178/18/20178/17/2017 4:20:07 PMPCANC
Field Super: Jason Shipp (re-inspect) Phone #: ###-#### >> Inspection requested via web by Lisa Whitney Inspection cancelled from web by: Lisa Whitney