BLD07-03283
| FIRE-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 4:02:53 PM | P | PASS |
|
|
Jim- fire life safety Phone #: ###-####
|
FIR08-00517
| INSP-Sprinkler Rough-in/Hydro | 8/18/2008 | 8/19/2008 | 8/19/2008 4:00:01 PM | P | PART |
|
|
OH install at the restroom, lounge and elevator lobby sheetrock lid ceilings is okay for cover, one head in a wall to be relocated, pendent heads at hard lid soffits are okay pending two heads supplied by a single one inch outlet is approved.
|
BLD08-00753
| FIRE-Final Inspection | 8/19/2008 | 8/19/2008 | 8/19/2008 3:49:57 PM | P | PASS |
|
|
Fire life safety finaled.
|
BLD07-03281
| FIRE-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 3:41:30 PM | P | PASS |
|
|
Life safety inspection passed.
|
BLD07-03282
| FIRE-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 3:39:59 PM | P | FAIL |
|
|
Need project related fire sprinkler permit finaled, also need to provide signage at the fire access lane per review comments.
|
FIR08-00361
| INSP-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 3:36:13 PM | P | FAIL |
|
|
Provide "911" signs at the outside bells, noted light fixture obstructions at some locations, provide missing head boxes and stock of spare sprinklers, secure signage at the control valve for the north unit, need to complete alarm bell testing, provide plans and review notes on site for verification of conditions met at next inspection, missing NFPA 25's.
|
FIR07-00863
| INSP-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 12:52:48 PM | A | PART |
|
|
Riser tamper and alarm supervision tested okay, forward flow completed, need to request project related UG permit for final, final walkthrough not completed at this time.
|
FIR08-00151
| INSP-Alarm Testing | 8/19/2008 | 8/19/2008 | 8/19/2008 12:50:41 PM | A | FAIL |
|
|
Fire alarm system field testing completed however reciept of signals could not be verifed due to lack of account monitoring set up, need to complete NFPA 72 inspection and testing forms including a list of singals prior to final, provide plans reflecting field changes including deleted notification devices, deleted elevator hoistway detectors, changed battery to 18 AH, provide accurate map at the panel, post signage at the door to the FACP room, change descriptor at riser #2 to read "antifreeze system", need to test main door mag lock interconnection to the fire alarm when finished.
|
FIR08-00279
| INSP-Supply line flush | 8/18/2008 | 8/19/2008 | 8/19/2008 11:22:19 AM | A | PART |
|
|
UG fire supply line flush completed.
|
FIR08-00279
| INSP-Sprinkler Rough-in | 8/18/2008 | 8/19/2008 | 8/19/2008 10:49:55 AM | A | DEFR |
|
|
Duplicate inspection request.
|
BLD08-00177
| FIRE-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 10:42:47 AM | A | PASS |
|
|
Repairs have been completed, fire life safety passed.
|
BLD08-00854
| FIRE-Final Inspection | 8/18/2008 | 8/19/2008 | 8/19/2008 10:15:05 AM | A | PASS |
|
|
Noted corrections verified for compliance, life safety inspection passed.
|
FIR08-00289
| INSP-Conference | 8/8/2008 | 8/19/2008 | 8/19/2008 10:14:08 AM | A | DONE |
|
|
9:00 a.m. on site conference inspection with all trades - for any questions contact Jim Storey
|