Inspections for the day of: Monday, August 19, 2019.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01623 Final8/19/20198/19/20198/19/2019 3:12:16 PMPPASS
Just call me for entry and I will meet you there Phone #: ###-#### Inspection requested via web by bob pond
- final ok
MEC19-02178 Final8/19/20198/19/20198/19/2019 2:54:39 PMPFAIL
door code 0911 / access through alley (easiest) Phone #: ###-#### Inspection requested via web by Joseph Profitt
- gas line needs supported in laundry room
- water heater flue needs 1" clearances at ceiling and needs supported
- a 2nd A/C is installed for existing home to the west need to see a permit pulled.
MEC19-03546 Rough-in8/19/20198/19/20198/19/2019 2:28:43 PMPPASS
Inspection requested via web by Konrad Swartz
- R/I ok
- still need access to home to check ductwork to man J
- fixture count shows a range vent being installed will need to see venting.
- check equipment to man J at final
MEC19-03686 Final8/17/20198/19/20198/19/2019 2:13:39 PMPPASS
Inspection requested via web by Jeff Glynn
- furnace ac coil co ok
MEC19-03360 Final8/15/20198/19/20198/19/2019 1:53:58 PMPNH
Please have inspector call Home Owner Wendy when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- no access to home called homeowner and no answer
MEC19-03576 Final8/12/20198/19/20198/19/2019 1:45:47 PMPPASS
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
- A/C coil co ok
MEC19-03518 Final8/14/20198/19/20198/19/2019 1:35:16 PMPPASS
Homeowners Scott ; Barbara ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- A/C coil co ok
MEC19-03152 Final8/13/20198/19/20198/19/2019 1:23:09 PMPPASS
Field super: Chad Robertson
PLEASE CALL HOME OWNER NORM ###-#### 1/2 BEFORE GOING THANK YOU. Phone #: ###-#### Inspection requested via web by Lisa Whitney
- A/C coil co ok
MEC19-02521 Final8/19/20198/19/20198/19/2019 1:22:40 PMPNR
Andrea Phone #: ###-####
- not ready
MEC19-03681 Pressure Test8/16/20198/19/20198/19/2019 11:20:51 AMAPASS
Phone #: ###-#### Inspection requested via web by Chris Field
- 20lb gas pressure test ok
MEC19-03644 Conference8/16/20198/19/20198/19/2019 10:50:46 AMPCANC
Dryer vent is around back of house exposed in new construction. Walk around west end of the house and the work is in the middle Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS
- dryer vent ok
MEC19-03644 Rough-in8/19/20198/19/20198/19/2019 10:50:25 AMPPART
Dryer vent is around back of house exposed in new construction. Walk around west end of the house and the work is in the middle Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS
- dryer vent R/I ok
MEC19-03685 Rough-in8/16/20198/19/20198/19/2019 10:48:53 AMAFAIL
Key is on top of the Idaho power meter located by the back door.
House is empty Phone #: ###-#### Inspection requested via web by Nicolas Barajas
- dryer vent is being smashed. Vent should be installed in a 2x6 wall or furred out to make room for vent
- need to see a transfer into laundry closet
MEC19-03683 Final8/16/20198/19/20198/19/2019 9:42:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Aaron Toomey
- mini split final ok
MEC19-03689 Rough-in8/19/20198/19/20198/19/2019 9:16:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- water heater flue pipe needs replaced screws penetrated inner liner
- both insulation shields need to maintain 1" clearances around flue
- fresh air duct needs connected to return plenum
- exhaust fans need installed/ ducting installed
MEC19-03688 Rough-in8/19/20198/19/20198/19/2019 9:15:35 AMAFAIL
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- water heater flue pipe needs replaced screws penetrated inner liner
- furnace insulation shield needs to maintain 1" clearances
MEC19-03688 Pressure Test8/19/20198/19/20198/19/2019 9:10:40 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- 20lb gas pressure test ok
- tagged meter location
MEC19-03689 Pressure Test8/19/20198/19/20198/19/2019 9:10:15 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- 20lb gas pressure test ok
- tagged meter location