Inspections for the day of: Wednesday, August 2, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD17-02490 BLD-Final8/2/20178/2/20178/2/2017 4:14:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Ira Rutledge
BLD17-02490 DOC - Permit Finaled8/2/20178/2/20178/2/2017 4:13:58 PMPPASS
BLD17-02551 BLD-Final8/2/20178/2/20178/2/2017 4:13:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Ira Rutledge
BLD17-02551 DOC - Permit Finaled8/2/20178/2/20178/2/2017 4:13:36 PMPPASS
BLD17-02196 DOC - Permit Finaled8/2/20178/2/20178/2/2017 4:11:20 PMPPASS
BLD16-03678 BLD-Conference8/2/20178/2/20178/2/2017 4:10:50 PMPPART
Mike Phone #: ###-#### stairs not ready ok to move belongs in no sleep over
BLD17-01494 BLD-Framing/Rough-in8/1/20178/2/20178/2/2017 3:15:34 PMPPART
Call half hour before // Scott Phone #: ###-#### conf
BLD16-00912 BLD-Final8/1/20178/2/20178/2/2017 2:56:56 PMPPASS
greg - call prior for access Phone #: ###-#### Permit was re-assigned to a "vanilla" tenant inprovement. Prior to future occupants the door hardware on the north doors will need to be changed to panic hardware, designated exits on the south and east side will need to be changed to single action door hardware with thumbturn deadbolts removed. There is an issued FIR permit for the commercial hood fire suppression system (FIR17-00079) but no inspection can be performed due to no cooking equipment being installed, prior to next tenant the issued FIR permit will need to be inspected and completed. No fire extinguishers
BLD16-00912 DOC - Permit Finaled8/2/20178/2/20178/2/2017 2:56:38 PMPPASS
Permit was re-assigned to a "vanilla" tenant inprovement. Prior to future occupants the door hardware on the north doors will need to be changed to panic hardware, designated exits on the south and east side will need to be changed to single action door hardware with thumbturn deadbolts removed. There is an issued FIR permit for the commercial hood fire suppression system (FIR17-00079) but no inspection can be performed due to no cooking equipment being installed, prior to next tenant the issued FIR permit will need to be inspected and completed. No fire extinguishers
BLD17-00091 BLD-Wall Bracing8/1/20178/2/20178/2/2017 2:40:07 PMPPASS
Lee Phone #: ###-####1st floor area b interior sheer ok
BLD16-03419 BLD-Footing8/1/20178/2/20178/2/2017 1:12:37 PMPPASS
Lucas Phone #: ###-#### main bldg rebar ok ufer noted on plan 30 ft
BLD17-00593 BLD-Energy code compliance8/1/20178/2/20178/2/2017 11:07:17 AMANR
josj Phone #: ###-####
BLD17-00593 BLD-Framing/Rough-in8/1/20178/2/20178/2/2017 11:06:48 AMAPART
josj Phone #: ###-#### truss engineering a3 garage wall 5.5 is only 3.5// h1 end bearing required per engineering/ top plate must break on king studes or strap
BLD17-00926 BLD-Framing/Rough-in8/1/20178/2/20178/2/2017 9:26:50 AMAPASS
Dale Phone #: ###-#### pending trades