Inspections for the day of: Wednesday, August 2, 2017.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02494 Permanent Service8/1/20178/2/20178/2/2017 1:56:57 PMAPASS
If homeowner is not home call my cell ###-####. The panel is located in the backyard. There might be a crew in the backyard removing the tree that caused the initial problem. Phone #: ###-#### Inspection requested via web by Ben Garner p/s o/h rec ok. Overhead riser is strapped. Talked to contractorn he is going to add a strut strap to unistrut also. Manufacturer's email states the maleable fittings used to reduce from 2" to 1-1/4" for riser hub are approved for wet or outside locations.
ELE17-02421 Electrical Rough-In8/2/20178/2/20178/2/2017 1:44:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Jesse Simpson All items UL lilsted
ELE17-02489 Rough-In Permanent Service8/2/20178/2/20178/2/2017 1:40:35 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dustin Kuester Panel located on a firewall
ELE17-02487 Rough-In Permanent Service8/2/20178/2/20178/2/2017 1:39:46 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dustin Kuester Panel located on a firewall
ELE17-00988 Final8/2/20178/2/20178/2/2017 1:38:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Greg Idsinga ok final
ELE17-02057 Rough-In Permanent Service8/2/20178/2/20178/2/2017 12:35:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson p/s u/g n ok. WUI zone A, there are no soffit cans. All lighting is wall mount.
ELE17-01955 Final8/2/20178/2/20178/2/2017 10:57:32 AMPPASS
Phone #: ###-#### Inspection requested via web by jamie berg No other work has been done. Closing out permit.
ELE17-01954 Final8/2/20178/2/20178/2/2017 10:57:04 AMPPASS
Inspection requested via web by jamie berg No other work has been done. Closing out permit
ELE17-01953 Final8/2/20178/2/20178/2/2017 10:56:28 AMPPASS
Inspection requested via web by jamie berg No other work has been done. Closing out permit.
ELE17-02447 Final8/2/20178/2/20178/2/2017 10:55:30 AMPPASS
Phone #: ###-#### Inspection requested via web by jamie berg No other work has been done. Closing out permit.
ELE17-02500 Electrical Rough-In8/1/20178/2/20178/2/2017 10:12:25 AMAPASS
This is a slab on grad and I have a conduit to the island and a conduit to the fireplace Phone #: ###-#### Inspection requested via web by Neal Rumsey ok cover
ELE17-01596 Electrical Rough-In8/1/20178/2/20178/2/2017 10:11:30 AMAPASS
Floor heating- Bill Phone #: ###-#### ok cover
ELE17-01955 Permanent Service8/1/20178/2/20178/2/2017 9:17:11 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg p/s u/g n ok. Corrections needed to be made on work done by others. Centerline Elec corrected all items. 250.8(5) Self tapping sheetmetal screw was replaced with proper hardware. 110.14(A) Some strands of conductor were bent and smached outside of terminal.
ELE17-01954 Permanent Service8/1/20178/2/20178/2/2017 9:14:00 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg p/s u/g n ok. Corrections needed to be made on work done by others. Centerline Elec corrected all items as needed. 250.8(5) Correct hardware was used to install ground lug. Previous hard ware was wood or sheetmetal screw. 110.14(A) Not all strands of conductor were installed under terminal. Strands were bent and smashed outside lug.
ELE17-01953 Permanent Service8/1/20178/2/20178/2/2017 9:09:09 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg p/s u/g n ok. Corrections needed to be made from previous work done by others. Centerline Elec made all corrections to items listed below. 250.8(5)proper hardware was installed to replace self tapping sheet metal screw used to secure ground lug. 110.14(A) Some strands of conductor feeding house panel were not under terminal. Some strands bent and smashed outside of terminal
ELE17-02447 Permanent Service8/1/20178/2/20178/2/2017 9:01:01 AMAPASS
Phone #: ###-#### Inspection requested via web by jamie berg p/s u/g n ok. There were items to correct from previous work that was done. Centerline Elec was not the original installer. Centerline Elec did correct all listed NEC violations. 250.8(5) Machined screws needed to be installed to replace wood screw with star washer. 110.14(A) Connection of conductors to terminals feeding house did not have a good connection. Some strands were bent and smashed outside of lug.
ELE17-01943 Final8/1/20178/2/20178/2/2017 8:35:45 AMAPASS
Phone #: ###-#### Inspection requested via web by shane miller Ok final