Inspections for the day of: Thursday, August 2, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02616 Electrical Rough-In8/2/20188/2/20188/2/2018 1:48:11 PMPPASS
Need ceiling grid inspection. Phone #: ###-#### Inspection requested via web by Alan Lusk Ok cover ceilings throughout. Conduit for floor outlets to be installed sometime next week.
ELE18-02927 Permanent Service8/2/20188/2/20188/2/2018 1:20:54 PMPCANC
Temp power pole Phone #: ###-#### Inspection requested via web by Tyler Bowen Added inspection for a temp service not p/s.
ELE18-02927 Temporary Service8/2/20188/2/20188/2/2018 1:20:15 PMPPASS
t/s o/h n ok
ELE18-02780 Electrical Rough-In8/1/20188/2/20188/2/2018 12:52:37 PMACANC
ROUGH AND COVER INSP. Phone #: ###-#### Inspection requested via web by Angela Stears Re-scheduled for 8/3/18. Awaiting contractors phone call on newly moved wall overtop of outlet.
ELE18-02929 Temporary Service8/2/20188/2/20188/2/2018 12:38:22 PMPPASS
Call electrical contractor with any concerns. Jose Guerrero ###-#### Phone #: ###-#### Inspection requested via web by Jose Guerrero t/s u/g n ok
ELE18-02495 Final8/1/20188/2/20188/2/2018 12:38:00 PMPPASS
Phone #: ###-#### Inspection requested via web by Eric White Ok final. GFI protection on pool equipt operates properly. Auto cover key pad moved to within 50' requirement of equipt per code.
ELE18-02939 Temporary Service8/2/20188/2/20188/2/2018 11:30:59 AMPPASS
Phone #: ###-#### Inspection requested via web by William Andrews t/s u/g n ok
ELE18-01451 Final8/2/20188/2/20188/2/2018 10:32:30 AMAFAIL
there is temp. power to pool control panel from cord --30amp gfci breaker
permanent power will not be extended until remodel on house is finished. Phone #: ###-#### Inspection requested via web by ron spen cer
1. Junction box cover for pool blower needed.
2. 1 panel blank needed in pool panel.
3. Auto cover works, but lights inop.
4. Pool panel needs breakers labeled.
ELE18-01451 Conference8/2/20188/2/20188/2/2018 10:30:55 AMPDONE
Once permanent power is pulled to pool equipt, a ground work inspection will be needed before conduit is covered.
ELE18-01923 Final8/1/20188/2/20188/2/2018 10:10:27 AMAPASS
Garage 7373 Phone #: ###-#### Inspection requested via web by Heath Thomas Ok final.
ELE17-03187 Final8/2/20188/2/20188/2/2018 9:36:29 AMAPASS
requesting a final, thought we had done this last year but somehow got missed. A building contractor will be there all day. Please call if you have any questions. Thanks Todd Phone #: ###-#### Inspection requested via web by todd cline Ok final.
ELE18-02898 Electrical Rough-In8/1/20188/2/20188/2/2018 9:24:06 AMAPASS
Call Jay ###-#### Phone #: ###-#### Inspection requested via web by Seth Stears Ok cover. Installer was on site with all components. All components UL listed.
ELE18-02926 Permanent Service8/1/20188/2/20188/2/2018 9:11:04 AMAPASS
Call Eric, groundskeeper, to get access. ###-#### Phone #: ###-#### Inspection requested via web by Kent VanSchoiack Service needing rec due to fire. Power is for well pump for water for simplot property. p/s u/g rec ok