Inspections for the day of: Tuesday, August 20, 2013.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02243 Electrical Rough-In8/20/20138/20/20138/20/2013 3:21:30 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Mike Okamura
Nail plate closet wall in bed.
Nail plate kitchen and hall common wall.
Support MC out of stud channels.
Secure alluminum flex in center of stud to maintain 1 1/4" from stud surface.
ELE13-02235 Permanent Service8/19/20138/20/20138/20/2013 2:36:56 PMPFAIL
Please call Bryan at telephone number listed. He has some questions regarding the grounding at the service. Phone #: ###-#### >> Inspection requested via web by Bryan Atkins
250.58- Where a building is fed by more than 1 service the same grounding electrode system shall be used
ELE13-02151 Permanent Service8/19/20138/20/20138/20/2013 1:25:30 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Jim Williams
p/s u/g n ok
ELE13-01026 Final8/20/20138/20/20138/20/2013 12:57:41 PMPPASS
(2) items have been fixed. Garage code is 8833 if you need it. Phone #: ###-#### >> Inspection requested via web by Craig Korell
Final ok
ELE13-02236 Rough-In Permanent Service8/19/20138/20/20138/20/2013 12:41:10 PMPPASS
ok for Id power to reconnect Phone #: ###-#### >> Inspection requested via web by Randy Fletcher Rough in ok p/s u/g rec ok
ELE12-00053 ELE-Aging Inspection8/20/20138/20/20138/20/2013 11:01:56 AM DONE
Waiting on owner
ELE13-01410 Final8/19/20138/20/20138/20/2013 10:43:55 AMAPASS
Phone #: ###-#### >> Inspection requested via web by steve sellers Final ok
ELE13-02186 Final8/15/20138/20/20138/20/2013 10:07:26 AMAFAIL
Joshalyn ###-#### gas furnace 40 amp breaker installed on a 30 amp max unit
ELE13-02186 Electrical Rough-In8/15/20138/20/20138/20/2013 10:06:00 AMAPASS
Joshalyn ###-#### gas furnace
Rough in ok
ELE13-02098 Electrical Rough-In8/19/20138/20/20138/20/2013 9:37:22 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman
Basement rough in ok cover
ELE13-02206 Temporary Service8/20/20138/20/20138/20/2013 9:17:26 AMAPASS
Temporary Overhead Power Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s o/h n ok