Inspections for the day of: Tuesday, August 20, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01927 Electrical Rough-In8/20/20198/20/20198/20/2019 3:08:39 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Grid and cloud rough in ok cover
ELE19-02424 Electrical Rough-In8/19/20198/20/20198/20/2019 2:36:40 PMPPASS
Please call Lynn prior to arrival. A ceiling grid inspection is needed. Phone #: ###-#### Inspection requested via web by Lynn Proctor
Grid rough in ok cover
ELE19-02735 Final8/20/20198/20/20198/20/2019 2:03:10 PMPPASS
Please Call approximately 1/2 hour before you get there so I can be there to get you in the right places for this inspection, thank you. Phone #: ###-#### Inspection requested via web by Rick Beckman
Card signed. Final ok.
ELE19-02733 Final8/20/20198/20/20198/20/2019 2:02:23 PMPPASS
Please Call approximately 1/2 hour before you get there so I can be there to get you in the right places for this inspection, thank you. Phone #: ###-#### Inspection requested via web by Rick Beckman
Card signed. Final ok.
ELE19-02719 Final8/19/20198/20/20198/20/2019 1:12:43 PMPFAIL
Phone #: ###-#### Inspection requested via web by Ron Smith
110.3- Missing dead front on AC combiner box. Cover leaning against fence.
110.12(A)- Unused openings shall be closed by approved means. Missing KO in bottom of disconnect.
ELE19-03089 Temporary Service8/20/20198/20/20198/20/2019 1:03:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE19-03102 Electrical Rough-In8/19/20198/20/20198/20/2019 11:29:19 AMAPASS
Entry doorbell doesn''t work, shake door to alert staff if locked. Any questions call Kory Phone #: ###-#### Inspection requested via web by Kory Peterson
Enter west parking lot room located at fouth end. Walls and hardlids rough in ok cover
ELE19-02312 Electrical Rough-In8/20/20198/20/20198/20/2019 10:56:48 AMANH
Underground inspection Phone #: ###-#### Inspection requested via web by Tyler Bowen Pictures of underground on file. Work was done after hours and backfilled for safety reasons.
Unable to located work being performed. Waited 10 minutes no return phone call. Recall when available
ELE19-03063 Rough-In Permanent Service8/19/20198/20/20198/20/2019 10:23:00 AMACANC
Phone #: ###-#### Inspection requested via web by Darryn Coburn
See seperate rough in and permanent service notes.
ELE19-03063 Permanent Service8/20/20198/20/20198/20/2019 10:22:51 AMPFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn
110.3- Acorn clamp shall be installed as per instructions. Connection to concrete encased electrode loose.
ELE19-03063 Electrical Rough-In8/20/20198/20/20198/20/2019 10:21:40 AMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
House rough in ok cover
ELE19-03097 Temporary Service8/19/20198/20/20198/20/2019 9:47:22 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE18-04687 Final8/19/20198/20/20198/20/2019 9:30:21 AMAFAIL
Phone #: ###-#### Inspection requested via web by Alan Lusk
210.8- All 120 volt 15 or 20 amp receptacle outlets located in a garage shall have GFCI protection. 9010 vacuum.