Inspections for the day of: Thursday, August 21, 2014.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02430 ELE-Aging Inspection8/21/20148/21/20148/21/2014 3:51:57 PM DONE
Waiting for contractor to schedule
ELE12-02951 ELE-Aging Inspection8/21/20148/21/20148/21/2014 3:50:03 PM DONE
Drove by and inspected
ELE12-02951 Final8/21/20148/21/20148/21/2014 3:49:16 PMPPASS
UL listing and disc. confirmed Final ok
ELE14-02017 Final8/21/20148/21/20148/21/2014 3:36:46 PMPPASS
late afternoon Phone #: ###-#### Inspection requested via web by Harvey Reyna Final ok
ELE14-01878 Final8/21/20148/21/20148/21/2014 3:14:22 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
ELE14-02281 Final8/21/20148/21/20148/21/2014 2:34:41 PMPPASS
final on 200amp service upgrade any questions call Clint @ ###-#### Phone #: ###-#### Inspection requested via web by Andy Rose Final ok
ELE14-02322 Temporary Service8/21/20148/21/20148/21/2014 2:02:36 PMPPASS
Over head temp pole, Shiloh builders sign at front of lot. Closest cross street, Warren and Division. Phone #: ###-#### Inspection requested via web by Robert Schroder t/s o/h n ok
ELE14-02066 Permanent Service8/21/20148/21/20148/21/2014 1:28:50 PMPCANC
Need a uffer and a permanent service inspection. If you have any questions please contact Lonny Baum. Phone #: ###-#### Inspection requested via web by Vicki Moore Rough in needed
ELE14-02066 Electrical Rough-In8/21/20148/21/20148/21/2014 1:28:30 PMPPASS
Need a uffer and a permanent service inspection. If you have any questions please contact Lonny Baum. Phone #: ###-#### Inspection requested via web by Vicki Moore Building K service underground, generator underground, concrete encased rough in ok cover
ELE14-02324 Rough-In Permanent Service8/21/20148/21/20148/21/2014 1:00:19 PMPFAIL
call ###-#### for access code, home is vacant Phone #: ###-#### Inspection requested via web by David Nelson Unable to verify grounding electrode system, 2 ground rods shall be added.
ELE14-02271 Electrical Rough-In8/21/20148/21/20148/21/2014 12:34:07 PMPPASS
Earlier the better - Laurie Phone #: ###-#### Patio ceiling and house wall rough in ok cover
ELE14-02303 Final8/21/20148/21/20148/21/2014 12:09:34 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
ELE14-02303 Electrical Rough-In8/21/20148/21/20148/21/2014 12:09:06 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok
ELE14-01963 Electrical Rough-In8/21/20148/21/20148/21/2014 11:38:03 AMAPASS
Underground rough-in of feeders entering south end of building and underground in NW corner of building. Phone #: ###-#### Inspection requested via web by Rafael Castillo Service conduit S.W. corner and branch circuit conduits N.W coner headed south rough in ok cover
ELE14-02186 Rough-In Permanent Service8/20/20148/21/20148/21/2014 11:09:35 AMACANC
Mitch Bulthuis Phone #: ###-#### Needed rough in only
ELE14-02186 Electrical Rough-In8/21/20148/21/20148/21/2014 11:08:14 AMPPASS
Mitch Bulthuis Phone #: ###-#### 90 degree wall in kitchen only rough in ok cover
ELE14-01248 Final8/20/20148/21/20148/21/2014 9:28:33 AMAPASS
Bill Phone #: ###-#### Final ok
ELE14-02305 Final8/20/20148/21/20148/21/2014 9:18:18 AMANR
Phone #: ###-#### Inspection requested via web by kendall bender See rough in
ELE14-02305 Electrical Rough-In8/20/20148/21/20148/21/2014 9:17:51 AMAFAIL
Phone #: ###-#### Inspection requested via web by kendall bender 210.63- A 120 volt 15 or 20 amp receptical outlet shall be located with in 25' of outdoor unit.
334.12- NM cable in seal tight not rated for damp location. BCC NM cable not permitted for church wiring.
Unable to verify 15 amp max fuse.
ELE14-02310 Final8/20/20148/21/20148/21/2014 8:40:58 AMAPASS
call Tina for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
ELE14-02310 Permanent Service8/21/20148/21/20148/21/2014 8:40:33 AMPPASS
call Tina for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg p/s o/h rec ok
ELE14-02017 Final8/20/20148/21/20148/21/2014 7:54:10 AMACANC
Phone #: ###-#### >> Inspection requested via web by Harvey Reyna Inspection cancelled from web by: Harvey Reyna
ELE14-02306 Final8/20/20148/21/20148/20/2014 4:32:40 PMAFAIL
Bill Phone #: ###-#### 250.50- when grounding electrode system is piping system it shall be supplemented by additional rods
ELE14-02306 Permanent Service8/20/20148/21/20148/20/2014 1:47:01 PMAPASS
Bill Phone #: ###-#### p/s o/h rec ok