Inspections for the day of: Thursday, August 21, 2014.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-03586 Pressure Test8/20/20148/21/20148/21/2014 4:46:38 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Gary Reeves - WHERE GAS PIPE PASSES THROUGH EXTERIOR WALL IT NEEDS TO BE WRAPPED WITH A INERT MATERIAL, NEED 18GA. YELLOW TRACER WIRE RAN WITH UNDERGROUND GAS LINE.
MEC14-03389 Conference8/21/20148/21/20148/21/2014 4:04:50 PMPCANC
WALK THROUGH WITH ERIC. SEE ERIC'S NOTES
MIS14-00115 MIS-Aging Inspection8/21/20148/21/20148/21/2014 3:46:18 PMPPEND
DRAKE MECH. DID THE WORK. i CAN'T FIND A PERMIT FOR THE WORK. THE OWNER IS CONTACTING THEM AND I AM GOING TO AS WELL.
MEC14-03290 Final8/21/20148/21/20148/21/2014 3:16:44 PMPPASS
Please call Evan 30 minutes prior for access, ###-####. Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-03539 Rough-in8/21/20148/21/20148/21/2014 2:01:17 PMPFAIL
As late as possible. Thanks. Phone #: ###-#### >> Inspection requested via web by April Thomas - CORRECTIONS NOT MADE
MEC14-03610 Final8/21/20148/21/20148/21/2014 1:59:26 PMPNR
Mid to late, will need flue test witnessed. Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-03444 Final8/20/20148/21/20148/21/2014 1:24:01 PMPPASS
Please call ahead to Anna Robins @ ###-#### for Final Inspection Phone #: ###-#### >> Inspection requested via web by Bailey Esposito
MEC14-03605 Final8/21/20148/21/20148/21/2014 12:54:44 PMPNR
Phone #: ###-#### >> Inspection requested via web by Angie Thome - NOT READY FOR FINAL, OKAY TO SHEET ROCK GARAGE
MEC14-03539 Rough-in8/20/20148/21/20148/21/2014 11:29:59 AMAFAIL
After 9:30 please. Phone #: ###-#### >> Inspection requested via web by April Thomas - FRESH AIR DUCT TO RETURN AIR PLENUM NEEDS TO BE 6", FLEX DUCT IN TGI ABOVE KITCHEN AREA CRUSHED WHERE IT GOES AROUND LIGHT, FLEX DUCT IN CRAWL IS LAYING ON THE GROUND NEEDS TO BE SUPPORTED, NEED TO INSULATE SUPPLY BOOT & ADJUSTABLE ELBOW IN CRAWL TO UTILITY ROOM.
MEC14-02982 Final8/21/20148/21/20148/21/2014 11:06:21 AMPPASS
Before 3pm please. Mike, ###-####. Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-03603 Rough-in8/20/20148/21/20148/21/2014 10:56:27 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - NEED TO VENT FURNACE, NEED TO RUN PRIMARY CONDENSATE DRAIN, NEED TO INSTALL CONDENSATE DRAIN PAN AND PIPE OUT OR INSTALL A WET SWITCH, NEED TO VENT BATH FANS, NEED TO RUN LINE SET, NEED TO INSTALL OUT SIDE AIR TO RETURN DUCT.
MEC14-03582 Rough-in8/20/20148/21/20148/21/2014 10:54:01 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - NEED INSULATION SHIELD ON B-VENT, NEED TO INSTALL CONDENSATE DRAIN PAN AND PIPE OUT OR INSTALL WET SWITCH, NEED TO SUPPORT LINE SET, NEED TO INSTALL OUT SIDE AIR DUCT TO RETURN.
MEC14-03582 Pressure Test8/20/20148/21/20148/21/2014 10:41:44 AMAPASS
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - 60LB GAS PRESSURE PASS
MEC14-03603 Pressure Test8/20/20148/21/20148/21/2014 10:41:13 AMAPASS
Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - 6OLB GAS PRESSURE PASS
MEC13-02785 Mec-Aging Inspection8/21/20148/21/20148/21/2014 10:28:58 AM CANC
MEC13-02904 Final8/19/20148/21/20148/21/2014 9:45:54 AMAPASS
Rick to meet Dixie at jobsite at 9am Thur....for final..
Phone #: ###-#### >> Inspection requested via web by Rick Jones
MEC14-03587 Pressure Test8/20/20148/21/20148/21/2014 8:52:22 AMAPASS
Meet at 8:00 On site contact ###-####.
Contact Tim with questions ###-####. Phone #: ###-#### >> Inspection requested via web by Lea Briggs - 20LB GAS PRESSURE PASS
MEC14-02210 Final8/20/20148/21/20148/21/2014 7:23:18 AMACANC
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell Inspection cancelled from web by: Joe Bertwell