ELE05-03001
| Permanent Service | 8/22/2005 | 8/22/2005 | 8/22/2005 4:21:54 PM | P | FAIL |
|
|
lee; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. posted called needs 2 grd rods, and bonding jumper to bond bushing shall terminate at neutral bus not can
|
ELE05-03073
| Final | 8/22/2005 | 8/22/2005 | 8/22/2005 3:46:19 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer no final cor. posted met contractor110.26(F)(2) dedicated space for p/s, 250.52(A)(1),104(A)(1) grd or bond p/s, 250.53 needs 2 grd rods, 250.148 terminate equip grds togegether and tag j box, 110.3(B) load conductors shall not be in line side or p/s, B.C.C. no violations to be retained
|
ELE05-02290
| Permanent Service | 8/22/2005 | 8/22/2005 | 8/22/2005 2:58:44 PM | P | PASS |
|
|
loren; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s o/h rec. ok
|
ELE05-03078
| Rough-In Permanent Service | 8/22/2005 | 8/22/2005 | 8/22/2005 2:21:15 PM | P | FAIL |
|
|
ron- ###-#### cor.and do not cover posted called 210.52(A&B) add outlet in liv rm, din rm outlet shall not serve for oulet in liv rm, 300.4(A)(1) nail plates , 410.8 clearence closet fixture
|
ELE05-03077
| Temporary Service | 8/22/2005 | 8/22/2005 | 8/22/2005 1:39:59 PM | P | PASS |
|
|
###-#### - brandon t/s o/h new ok
|
ELE05-02885
| Final | 8/19/2005 | 8/22/2005 | 8/22/2005 1:17:03 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher this is for r/i not final, cor. posted called left message 314. 17 replace 2 gang box broken clamp, 210.52(A) 2ft wall, 6ft 12ft,210.12 arc fault all circuits in bed rm, 310.16 protect #14 at 15 amps , shall not feed bed rm from laundry circuit, 300.4(A)(1)&(D)
|
ELE04-03054
| Electrical Rough-In | 8/22/2005 | 8/22/2005 | 8/22/2005 12:18:51 PM | P | PART |
|
|
FOUNTAIN UNDERGROUND INSPECTION PLEASE.; Phone #: ###-#### Internet Inspection Request from: Barry Kendall cooridor ceilings and fountain bond anop
|
ELE05-02806
| Electrical Rough-In | 8/20/2005 | 8/22/2005 | 8/22/2005 10:24:38 AM | A | FAIL |
|
|
Inspection for under slab electrical. area needed is in main floor where the concrete has been removed and is ready to be replaced; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen cor. posted called BCC u/g covered before inspection
|
ELE05-03066
| Rough-In Permanent Service | 8/19/2005 | 8/22/2005 | 8/22/2005 10:04:01 AM | A | PASS |
|
|
bob- ###-#### r/i house ,garage , and u/g ok p/s o/h new ok
|
ELE05-03065
| Electrical Rough-In | 8/19/2005 | 8/22/2005 | 8/22/2005 9:36:31 AM | A | PASS |
|
|
paul ###-#### r/i ok
|
ELE05-02346
| Rough-In Permanent Service | 8/22/2005 | 8/22/2005 | 8/22/2005 8:47:02 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 8/22/2005 at 6:26:37 AM. Contact: ###-####. see added p/s, cor. posted for owner low voltage wiring shall be done by licensed contractor, 314.17 ent needs connectors, and 300.4 (A)(1)&(D)
|
ELE05-02346
| Permanent Service | 8/22/2005 | 8/22/2005 | 8/22/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/22/2005 at 6:26:37 AM. Contact: ###-####. p/s u/g new ok , meter for house panel only
|
ELE05-02439
| DOC - Permit Finaled | 8/22/2005 | 8/22/2005 | 8/22/2005 12:00:00 AM | P | PASS |
|
|
owners permit finaled contractor has new permit for job, owner had someone else wire the job on his permit
|