Inspections for the day of: Monday, August 22, 2005.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03001 Permanent Service8/22/20058/22/20058/22/2005 4:21:54 PMPFAIL
lee; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
cor. posted called needs 2 grd rods, and bonding jumper to bond bushing shall terminate at neutral bus not can
ELE05-03073 Final8/22/20058/22/20058/22/2005 3:46:19 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer no final cor. posted met contractor110.26(F)(2) dedicated space for p/s, 250.52(A)(1),104(A)(1) grd or bond p/s, 250.53 needs 2 grd rods, 250.148 terminate equip grds togegether and tag j box, 110.3(B) load conductors shall not be in line side or p/s, B.C.C. no violations to be retained
ELE05-02290 Permanent Service8/22/20058/22/20058/22/2005 2:58:44 PMPPASS
loren; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
p/s o/h rec. ok
ELE05-03078 Rough-In Permanent Service8/22/20058/22/20058/22/2005 2:21:15 PMPFAIL
ron- ###-#### cor.and do not cover posted called 210.52(A&B) add outlet in liv rm, din rm outlet shall not serve for oulet in liv rm, 300.4(A)(1) nail plates , 410.8 clearence closet fixture
ELE05-03077 Temporary Service8/22/20058/22/20058/22/2005 1:39:59 PMPPASS
###-#### - brandon t/s o/h new ok
ELE05-02885 Final8/19/20058/22/20058/22/2005 1:17:03 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher this is for r/i not final, cor. posted called left message 314. 17 replace 2 gang box broken clamp, 210.52(A) 2ft wall, 6ft 12ft,210.12 arc fault all circuits in bed rm, 310.16 protect #14 at 15 amps , shall not feed bed rm from laundry circuit, 300.4(A)(1)&(D)
ELE04-03054 Electrical Rough-In8/22/20058/22/20058/22/2005 12:18:51 PMPPART
FOUNTAIN UNDERGROUND INSPECTION PLEASE.; Phone #: ###-#### Internet Inspection Request from: Barry Kendall cooridor ceilings and fountain bond anop
ELE05-02806 Electrical Rough-In8/20/20058/22/20058/22/2005 10:24:38 AMAFAIL
Inspection for under slab electrical. area needed is in main floor where the concrete has been removed and is ready to be replaced; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen
cor. posted called BCC u/g covered before inspection
ELE05-03066 Rough-In Permanent Service8/19/20058/22/20058/22/2005 10:04:01 AMAPASS
bob- ###-#### r/i house ,garage , and u/g ok
p/s o/h new ok
ELE05-03065 Electrical Rough-In8/19/20058/22/20058/22/2005 9:36:31 AMAPASS
paul ###-#### r/i ok
ELE05-02346 Rough-In Permanent Service8/22/20058/22/20058/22/2005 8:47:02 AMAFAIL
Scheduled by a contractor via Hello! on 8/22/2005 at 6:26:37 AM. Contact: ###-####. see added p/s, cor. posted for owner low voltage wiring shall be done by licensed contractor, 314.17 ent needs connectors, and 300.4 (A)(1)&(D)
ELE05-02346 Permanent Service8/22/20058/22/20058/22/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 8/22/2005 at 6:26:37 AM. Contact: ###-####. p/s u/g new ok , meter for house panel only
ELE05-02439 DOC - Permit Finaled8/22/20058/22/20058/22/2005 12:00:00 AMPPASS
owners permit finaled contractor has new permit for job, owner had someone else wire the job on his permit