Inspections for the day of: Friday, August 22, 2008.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-01962 Final8/22/20088/22/20088/22/2008 4:44:11 PMPPASS
ok to final, no esc this project
ELE08-02345 Electrical Rough-In8/22/20088/22/20088/22/2008 3:53:18 PMPPASS
Under Ground. Late afternoon if possible 3:00 or 4:00 Phone #: ###-#### Internet Inspection Request from: Brandon Blackham u/g house to garage only ok to cover, corrections made, there are 4 90's from each end above ground, will need some type pulling box or fitting
ESC08-00527 General Inspection8/22/20088/22/20088/22/2008 3:21:48 PMPPART
looked ok
ESC08-00613 General Inspection8/22/20088/22/20088/22/2008 2:55:35 PMPPART
looked ok
ESC08-00084 General Inspection8/22/20088/22/20088/22/2008 2:25:26 PMAPART
looked ok
ELE08-02351 Electrical Rough-In8/22/20088/22/20088/22/2008 1:42:31 PMPPASS
Andy- call for access Phone #: ###-#### ric ok, no esc this project
ELE08-02348 Electrical Rough-In8/22/20088/22/20088/22/2008 12:43:32 PMPPASS
Inspect trench for floor outlets in basement Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot u/g only ok to cover
ELE08-02325 Electrical Rough-In8/20/20088/22/20088/22/2008 10:28:08 AMAPASS
switch and recep for garbage disposal is ready Phone #: ###-#### Internet Inspection Request from: gary batten ri ok, no esc this project
ELE08-02325 Final8/22/20088/22/20088/22/2008 10:27:53 AMAPASS
switch and recep for garbage disposal is ready Phone #: ###-#### Internet Inspection Request from: gary batten ok to final, no esc this project
ELE08-01448 Final8/21/20088/22/20088/22/2008 9:30:39 AMAPASS
mike Phone #: ###-#### met contractor, left survey, NEC 210.70 shall provide lighting outlet at garage man door, ok to final, no esc this project
ELE08-02345 Electrical Rough-In8/21/20088/22/20088/22/2008 8:47:10 AMAFAIL
Brandon underground Phone #: ###-#### called contractor, left correction notice, NEC 300.5 minimum burial depth for pvc shall be 18" to top of raceway
ELE08-01563 Electrical Rough-In8/21/20088/22/20088/22/2008 8:18:17 AMAPART
Jason Phone #: ###-#### walls only 1st floor parts anop