BLD08-00892
| BLD-Final | 8/22/2008 | 8/22/2008 | 8/22/2008 5:25:25 PM | P | NR |
|
|
Dave Phone #: ###-####. Needs elec, and fire/life/safety finals. Contractor was contacted.
|
BLD06-02320
| BLD-Conference | 8/22/2008 | 8/22/2008 | 8/22/2008 3:54:56 PM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Bob Thornton.. On site to review opening protection for can lights in floor ceiling assemblies, a second layer of 5/8 type X needs added for box outs, firecaulk seems. Also inspected lid on 4thfloor corridor for pre rock, some areas still need to be firecaulked, and some additional straps need to be added at roof drain penetrations through top plates.
|
ESC06-01309
| Random Inspection | 8/22/2008 | 8/22/2008 | 8/22/2008 3:49:00 PM | P | PASS |
|
|
|
BLD07-03282
| BLD-Final | 8/21/2008 | 8/22/2008 | 8/22/2008 2:03:25 PM | P | NR |
|
|
jim Phone #: ###-####. Needs fire/life/safety.
|
BLD07-03283
| BLD-Final | 8/21/2008 | 8/22/2008 | 8/22/2008 2:02:52 PM | P | PASS |
|
|
jim Phone #: ###-####. ok for perm occ.
|
BLD08-00949
| BLD-Final | 8/21/2008 | 8/22/2008 | 8/22/2008 11:31:29 AM | A | NR |
|
|
Scheduled by a contractor via Hello! on 8/21/2008 at 8:23:37 AM. Contact: ###-####. Contacted contractor and told him that he still needed code enforcement and life/safety finals.
|
ESC08-00547
| Site Final | 8/22/2008 | 8/22/2008 | 8/22/2008 10:42:35 AM | A | PASS |
|
|
site is clean, reveg. is ok.
|
BLD08-01357
| BLD-Final | 8/21/2008 | 8/22/2008 | 8/22/2008 10:41:36 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/21/2008 at 1:47:17 PM. Contact: ###-####. ok for perm occ.
|
ESC08-00357
| Random Inspection | 8/22/2008 | 8/22/2008 | 8/22/2008 10:07:18 AM | A | PASS |
|
|
ESC permit sign posted. Site was clean. ok.
|
BLD08-00881
| BLD-Framing/Rough-in | 8/21/2008 | 8/22/2008 | 8/22/2008 10:06:02 AM | A | PASS |
|
|
shallan Phone #: ###-####
|
ESC08-00613
| Site Preparation | 8/22/2008 | 8/22/2008 | 8/22/2008 9:42:08 AM | A | PASS |
|
|
ESC permit sign posted. site lokked ok.
|
BLD08-01554
| BLD-Footing | 8/20/2008 | 8/22/2008 | 8/22/2008 9:41:35 AM | A | PART |
|
|
Josh Phone #: ###-####. perimeter footings for garage, Needs to add verts at 16" oc across front of garage as noted on approved plans.
|
BLD08-01015
| BLD-Framing/Rough-in | 8/21/2008 | 8/22/2008 | 8/22/2008 9:12:11 AM | A | PART |
|
|
mick - please call 1/2 hr prior so he can meet you there Phone #: ###-####. ok to cover 2nd side of 2hr. fire barrier wall.
|