ELE12-00227
| ELE-Aging Inspection | 8/22/2014 | 8/22/2014 | 8/22/2014 3:55:40 PM | | CANC |
|
|
Too busy
|
ELE14-02207
| Rough-In Permanent Service | 8/22/2014 | 8/22/2014 | 8/22/2014 3:54:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
|
ELE14-00479
| Electrical Rough-In | 8/22/2014 | 8/22/2014 | 8/22/2014 3:12:02 PM | P | FAIL |
|
|
Robert Phone #: ###-#### 230.79- Detached garage with more than 2 circuits shall have 60 amp feed minimum. Detached garage shall have disconnecting means. Conductors feeding haot tub shall be of sufficient size. 334.30 NM cable shall be secured with in 8" of box with open entry.
|
ELE14-01963
| Electrical Rough-In | 8/22/2014 | 8/22/2014 | 8/22/2014 2:25:24 PM | P | PASS |
|
|
Underground northwest conduit. Phone #: ###-#### Inspection requested via web by Rafael Castillo Re inspected S.W. service conduit and west branch circuit conduit runs. Rough in ok cover
|
ELE14-01410
| Final | 8/22/2014 | 8/22/2014 | 8/22/2014 1:46:20 PM | P | PASS |
|
|
Please call with any questions Phone #: ###-#### Inspection requested via web by mike brown Final ok
|
ELE14-01182
| Electrical Rough-In | 8/22/2014 | 8/22/2014 | 8/22/2014 12:53:36 PM | P | PASS |
|
|
Soffit 2nd floor in front of elevator. Shane is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Mike Basye CH2 soffit by elevator 2 cans rough in ok cover
|
ELE14-02323
| Electrical Rough-In | 8/21/2014 | 8/22/2014 | 8/22/2014 12:26:24 PM | P | PASS |
|
|
We are requesting a inspection for a cover for a soffit for tomorrow afternoon. Our onsite contact is Luke Hardy @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Soffit rough in ok core
|
ELE14-00157
| Electrical Rough-In | 8/20/2014 | 8/22/2014 | 8/22/2014 12:07:38 PM | A | FAIL |
|
|
3rd floor rough-in Phone #: ###-#### Inspection requested via web by Tom Betty 300.4 nail plates, secure NM 1 1/4" form stud surface, support NM with in 12" of boxes and shall not be more than 4 1/2' between supports
|
ELE13-02557
| Electrical Rough-In | 8/21/2014 | 8/22/2014 | 8/22/2014 10:53:38 AM | A | PART |
|
|
David Phone #: ###-#### OK insulate only. Shall have minimum 6" of workable wire in each box. Shall nail plate notched studs to protect NM calbe from physical damage
|
ELE14-02203
| Electrical Rough-In | 8/21/2014 | 8/22/2014 | 8/22/2014 10:15:46 AM | A | PASS |
|
|
potting for lights and deck cups Phone #: ###-#### Inspection requested via web by Kevin Koomler Rough in ok cover
|
ELE14-01417
| Final | 8/21/2014 | 8/22/2014 | 8/22/2014 9:59:24 AM | A | PASS |
|
|
Homeowners state they will be on premise today. Dustin is at ###-####. Jim is at ###-####. Thanks. Phone #: ###-#### Inspection requested via web by Paula Gratiot Final ok
|
ELE14-02306
| Final | 8/21/2014 | 8/22/2014 | 8/22/2014 9:25:54 AM | A | PASS |
|
|
Joe Phone #: ###-#### Final ok
|
ELE14-01703
| Final | 8/21/2014 | 8/22/2014 | 8/22/2014 9:11:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher UL listing and disconnect confirmed. Final ok
|
ELE14-02330
| Permanent Service | 8/21/2014 | 8/22/2014 | 8/22/2014 8:59:50 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Celinda Winters Green house located on south east bldg. p/s o/h n ok
|
ELE14-02326
| Final | 8/21/2014 | 8/22/2014 | 8/22/2014 8:33:59 AM | A | PASS |
|
|
Power has been disconnected over a year Phone #: ###-#### Inspection requested via web by cory carman Final ok
|
ELE14-02326
| Permanent Service | 8/22/2014 | 8/22/2014 | 8/22/2014 8:33:58 AM | P | PASS |
|
|
Power has been disconnected over a year Phone #: ###-#### Inspection requested via web by cory carman p/s o/h rec ok
|
ELE14-02326
| Permanent Service | 8/22/2014 | 8/22/2014 | 8/22/2014 8:33:42 AM | P | PASS |
|
|
Power has been disconnected over a year Phone #: ###-#### Inspection requested via web by cory carman p/s o/h rec ok
|