PLM17-02639
| Water and/or Sewer | 8/22/2017 | 8/22/2017 | 8/24/2017 9:47:10 AM | P | PASS |
|
|
|
PLM17-00146
| PLM-Aging Inspection | 8/22/2017 | 8/22/2017 | 8/23/2017 8:25:18 AM | | PEND |
|
|
contractor to schedule
|
PLM17-00143
| PLM-Aging Inspection | 8/22/2017 | 8/22/2017 | 8/23/2017 8:18:00 AM | | PEND |
|
|
Contractor to complete and schedule
|
PLM17-03143
| Water Heater Final | 8/21/2017 | 8/22/2017 | 8/22/2017 5:53:21 PM | P | PASS |
|
|
PLEASE CALL BEFORE ARRIVAL. THANK YOU Phone #: ###-#### Inspection requested via web by JEREMY LINK
|
PLM17-03156
| Final | 8/22/2017 | 8/22/2017 | 8/22/2017 5:24:58 PM | P | FAIL |
|
|
late pm please call Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss. The water softener drain is draining into a floor drain under the water heater without an air gap. The water softener drain must have a minimum of a 1" air gap. A stand pipe could be installed into the floor drain vent off a trap in the wall.
|
PLM17-01748
| Plumbing Rough-in | 8/22/2017 | 8/22/2017 | 8/22/2017 4:23:59 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jeff Coate. Water and sewer permit has not been pulled. Do not cover work until permit is pulled.
|
PLM17-02123
| Final | 8/21/2017 | 8/22/2017 | 8/22/2017 4:11:34 PM | P | PASS |
|
|
3162 ENTER Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-02221
| Water and/or Sewer | 8/22/2017 | 8/22/2017 | 8/22/2017 4:01:02 PM | P | PASS |
|
|
waterline Phone #: ###-#### Inspection requested via web by Patrick Feely
|
PLM17-02221
| Final | 8/22/2017 | 8/22/2017 | 8/22/2017 4:00:51 PM | P | PASS |
|
|
waterline Phone #: ###-#### Inspection requested via web by Patrick Feely
|
PLM17-02565
| Final | 8/22/2017 | 8/22/2017 | 8/22/2017 3:40:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM17-03158
| Groundwork | 8/22/2017 | 8/22/2017 | 8/22/2017 3:20:07 PM | P | PASS |
|
|
Please call Travis to get the code to the lock box to gain access to the building. Thank You. Phone #: ###-#### Inspection requested via web by Travis Baker
|
PLM17-03020
| Final | 8/16/2017 | 8/22/2017 | 8/22/2017 2:57:17 PM | P | PASS |
|
|
Please call ###-#### when on way Phone #: ###-#### Inspection requested via web by Ben Davis
|
PLM17-01892
| Final | 8/22/2017 | 8/22/2017 | 8/22/2017 2:41:32 PM | P | PASS |
|
|
if questions call Josh @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM17-03157
| Water Heater Final | 8/22/2017 | 8/22/2017 | 8/22/2017 2:28:12 PM | P | PASS |
|
|
EARLY PM INSPECTION IF POSSIBLE PLEASE INSTALLER: AL ###-#### THANK YOU Phone #: ###-#### Inspection requested via web by Ben Welgan. 20# pressure test and water heater install
|
PLM17-02639
| Plumbing Rough-in | 8/21/2017 | 8/22/2017 | 8/22/2017 12:33:36 PM | A | NR |
|
|
Pressurized water - Mike Phone #: ###-####
|
PLM17-02221
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 12:20:33 PM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Patrick Feely. OK to cover line. Need to make connections and test
|
PLM17-02936
| Sprinkler (Final) | 8/21/2017 | 8/22/2017 | 8/22/2017 11:59:29 AM | A | PASS |
|
|
Inspection requested via web by Ruben Gamez
|
PLM17-03043
| Other | 8/21/2017 | 8/22/2017 | 8/22/2017 11:54:09 AM | A | PASS |
|
|
Please call ahead to meet, questions on how to test line - Conference - Fred Phone #: ###-####. Remove enough concrete to get a full size end of line cleanout installed and roll vent off the center line of the drain
|
PLM17-02407
| Groundwork | 8/18/2017 | 8/22/2017 | 8/22/2017 11:39:18 AM | A | PART |
|
|
JOB CONTACT - RUSSELL ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Extend stay room and center janitor
|
PLM17-03071
| Plumbing Rough-in | 8/21/2017 | 8/22/2017 | 8/22/2017 11:03:30 AM | A | PART |
|
|
Call half hour before // Candice or ###-#### Michael Phone #: ###-#### The vent lines must come off above the center line of the drain on the shower and the relocated toilet.
|
PLM17-02259
| Plumbing Rough-in | 8/21/2017 | 8/22/2017 | 8/22/2017 10:27:38 AM | A | PASS |
|
|
if questions call Josh @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM17-03089
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 10:04:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM17-03089
| Final | 8/22/2017 | 8/22/2017 | 8/22/2017 10:04:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darren Wood
|
PLM17-03147
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:47:47 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. No pressure test on the water service. Check grade and support wye on the sewer connection.
|
PLM17-03153
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:46:59 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. No pressure test on the water service Check grade and support connection wye on the sewer.
|
PLM17-03152
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:46:07 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. No pressure test on the water service Check grade and support wye on the sewer connection.
|
PLM17-03151
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:45:19 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. Pressure test the water service. check grade on the connection wye on the sewer.
|
PLM17-03150
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:44:02 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. No pressure test on the water service. Check grade on the connection wye.
|
PLM17-03149
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:43:09 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. Pressure test the water service. Non approved pipe inside the foundation walls on the sewer.
|
PLM17-03148
| Water and/or Sewer | 8/21/2017 | 8/22/2017 | 8/22/2017 9:41:46 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by matt ford. Pressure test the water service. Non-approved pipe inside the foundation walls on the sewer.
|
PLM17-01156
| Final | 8/21/2017 | 8/22/2017 | 8/22/2017 8:32:48 AM | A | PASS |
|
|
JOB # 50682 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|