Inspections for the day of: Thursday, August 23, 2001.
Number of inspections: 4
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-01408 BLD-Aging Inspection8/23/20018/23/20018/23/2001 12:00:00 AM FAIL
no cal for insp. 8/23/2001 5:15:21 PM
BLD01-01115 BLD-Other8/23/20018/23/20018/23/2001 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 08/23/2001 at 07:43:41. Contact: ###-####. c/n on bld00955 aplies to this permit also. 8/23/2001 3:17:46 PM
BLD01-01623 BLD-Final8/23/20018/23/20018/23/2001 12:00:00 AMPPART
matt ###-#### need fire sign off and card. 8/24/2001 4:40:40 PM
BLD01-00955 BLD-Framing/Rough-in8/23/20018/23/20018/23/2001 12:00:00 AMPFAIL
1. (Stairway rise and run) The rise of steps and stairs shall not be less than 4 inches nor more than 7 inches. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Except as permitted for circular, winding, and spiral stairways, the run shall not be less than 11 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads or nosings. Stair treads shall be of uniform size and shape, except the largest tread run within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (1997 UBC 1003.3.3.3) Note the exception to tread and riser dimensions for private stairways and stairways to unoccupied roofs and. Also, note the exception to dimensions of risers adjoining a sloping public way. need per pln on one stair approved by planreview not per ubc. 2 3/8 anchor bolts must be replaced to 1/2 x 3 1/2 per engineering 4. saftey clips required on beams.5.barrior post protection at ends of racks in forklift route 6. handrail 34 to 38. 6. fire insp required. 8/23/2001 3:16:51 PM