Inspections for the day of: Monday, August 23, 2010.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01849 Permanent Service8/23/20108/23/20108/23/2010 4:47:07 PMPPASS
p/s o/h rec ok will inspect for final 8-24-10
ELE10-01787 Electrical Rough-In8/23/20108/23/20108/23/2010 3:40:54 PMPPASS
contact Jamey if you have any issues Phone #: ###-#### >> Inspection requested via web by shane farwell ri ok
ELE10-01787 Permanent Service8/23/20108/23/20108/23/2010 3:40:02 PMPPASS
contact Jamey if you have any issues Phone #: ###-#### >> Inspection requested via web by shane farwell p/s u/g n ok
ELE10-00971 Final8/21/20108/23/20108/23/2010 3:25:19 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov called, too many corrections to write, gave over phone to contractor, strap riser, check for clearance for service disconnect, identify service disconnect, provide bonding bar per NEC 250.94, kitchen island gfci shall operate, shall provide convenience receptacle in island, wire disposal, tighten loose receptacles in hall, coat rack, m bath
ELE10-01516 Final8/23/20108/23/20108/23/2010 3:03:55 PMPPASS
Someone will be there. If you have any questions, please call Clay. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan corrections made, ok final, signed card
ELE10-01710 Electrical Rough-In8/23/20108/23/20108/23/2010 2:25:15 PMPPASS
please give me a call half an hour before inspection to insure access. This a heated floor inspection. Thanks Shaun ###-#### >> Inspection requested via web by Shaun Kirkman ok cover floor heat only
ELE10-01831 Final8/20/20108/23/20108/23/2010 1:25:54 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Phil Baker ok final
ELE10-01840 Final8/23/20108/23/20108/23/2010 12:34:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok final
ELE10-01809 Electrical Rough-In8/21/20108/23/20108/23/2010 9:59:37 AMANH
Ring doorbell for access Phone #: ###-#### >> Inspection requested via web by daniel bibikov rang bell, no answer, left card, called, left message, fee due
ELE10-00680 Electrical Rough-In8/20/20108/23/20108/23/2010 9:06:51 AMAPASS
Reinspection of broken flex. Later in the morning if you can please. Phone #: ###-#### >> Inspection requested via web by Mark Sessions corrections made, ok cover ceilings
ELE10-01516 Final8/20/20108/23/20108/23/2010 8:13:06 AMAFAIL
Someone will be there Phone #: ###-#### >> Inspection requested via web by Clay Morgan called, left message, corrections not made, fee due, left card
ELE10-00563 ELE-Aging Inspection8/23/20108/23/20108/23/2010 6:27:31 AM DONE
suc
ELE08-03081 ELE-Aging Inspection8/23/20108/23/20108/23/2010 6:26:21 AM DONE
see doc expire
ELE08-03081 DOC - Permit Expired8/23/20108/23/20108/23/2010 6:26:08 AMAPASS
no activity
ELE08-01880 ELE-Aging Inspection8/23/20108/23/20108/23/2010 6:24:52 AM DONE
see doc expire
ELE08-01880 DOC - Permit Expired8/23/20108/23/20108/23/2010 6:24:39 AMAPASS
no activity