Inspections for the day of: Thursday, August 24, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02316 ELE-Aging Inspection8/24/20068/24/20068/24/2006 4:18:39 PM DONE
called, left message to call for final
ELE06-03153 Temporary Service8/24/20068/24/20068/24/2006 3:47:25 PMPPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/s o/h n ok
ELE06-02929 Rough-In Permanent Service8/24/20068/24/20068/24/2006 3:17:43 PMPPASS
joe; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr made ric ok, p/s u/g n ok
ELE06-03160 Permanent Service8/24/20068/24/20068/24/2006 2:04:19 PMPFAIL
Inspection for Afternoon. Thank you!; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contr, left corr notice, nec 230.24(A)exc3, bottom of drip loop shall be min 18" above roof line, 250.52(A)(3) and BCC concrete encased electrode shall be installed
ELE06-03168 Rough-In Permanent Service8/24/20068/24/20068/24/2006 1:12:01 PMPCANC
chad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see ri
ELE06-03168 Electrical Rough-In8/24/20068/24/20068/24/2006 1:11:37 PMPPASS
chad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to pour gec, ric ok, need to see gec before backfill
ELE06-02278 Final8/23/20068/24/20068/24/2006 11:48:25 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok to final
ELE06-02144 Final8/23/20068/24/20068/24/2006 10:35:35 AMAPASS
call for code; Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok to final
ELE06-03151 Permanent Service8/23/20068/24/20068/24/2006 10:20:40 AMAPASS
please call prior to inspection///###-#### pat p/s u/g rec ok
ELE06-02359 Final8/23/20068/24/20068/24/2006 9:50:45 AMAPASS
darryl; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok to final
ELE06-02360 Final8/23/20068/24/20068/24/2006 9:34:30 AMAPASS
darryl; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok to final
ELE06-03153 Temporary Service8/23/20068/24/20068/24/2006 8:57:08 AMACANC
Internet Inspection Request from: Latisha Peltier talked to contr, wrong address
ELE06-02633 Electrical Rough-In8/23/20068/24/20068/24/2006 8:53:31 AMAPASS
Partial rough-in steel stud walls only Contact Ric; Phone #: ###-#### Internet Inspection Request from: Celinda Winters ok to cover walls only plus bath lid
ELE06-02906 Electrical Rough-In8/23/20068/24/20068/24/2006 8:33:03 AMAFAIL
craig; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt met owner, left corr notice, nec 312.5 all conductors entering enclosures shall have abrasion protection, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.17(C) nm cable shall be secured within 8" of box, BCC all make-up shall be done-boxes set