Inspections for the day of: Wednesday, August 24, 2011.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC10-00843 Aging Inspection8/24/20118/24/20118/25/2011 2:29:57 PM DONE
looked ok
ELE11-01822 Electrical Rough-In8/24/20118/24/20118/24/2011 2:53:36 PMPPASS
Dave Phone #: ###-#### corrections made, ri ok
ELE11-01663 Final8/24/20118/24/20118/24/2011 2:33:13 PMPPASS
dan Phone #: ###-#### ok final
ELE11-01959 Permanent Service8/24/20118/24/20118/24/2011 2:04:41 PMPPASS
dan Phone #: ###-#### p/s u/g rec ok
ELE11-01032 Electrical Rough-In8/24/20118/24/20118/24/2011 1:29:49 PMPFAIL
ceiling cover is ready call with questions of concerns to corey''s number above or call me don @ ###-#### Phone #: ###-#### >> Inspection requested via web by Don Lustig called, shall strap conduit, close boxes, remove unused lv cable or tag as purpose
ELE11-00768 Permanent Service8/24/20118/24/20118/24/2011 12:42:15 PMPPASS
Rick Phone #: ###-#### p/s o/h rec ok
ELE11-01628 Electrical Rough-In8/23/20118/24/20118/24/2011 12:05:20 PMPPASS
bonding inspection on west fountain Phone #: ###-#### >> Inspection requested via web by Kevin Koomler bonding only ok west fountain, marked existing tag
ELE11-01940 Rough-In Permanent Service8/24/20118/24/20118/24/2011 10:29:58 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson ri ok, p/s u/g n ok
ELE11-01951 Electrical Rough-In8/23/20118/24/20118/24/2011 9:49:07 AMAPART
Contact: Brian Gee Partial rough in please Phone #: ###-#### >> Inspection requested via web by Deb Gooden bath and laundry only ok cover
ELE11-00716 Final8/23/20118/24/20118/24/2011 9:24:37 AMAFAIL
Victoria Phone #: ###-#### called, left correction notice, too many violations to list each code article, will supply on request, NEC and BCC, shall staple and protect ground conductor at service, shall provide in-use cover and weather proof box for front receptacle, all fixtures shall be mounted, closet fixture sahll be minimum 6" from shelf, shall provide 2 small appliance branch circuits and be gfci protected in kitchen, shall provide water heater disconnect, outlet up bedroom shall operate, main service shall have dead front installed and circuit schedule,dining room shall be gfci protected, shall provide 3' minimum access around outlets, only owner shall do any electrical work
ELE11-01864 Electrical Rough-In8/24/20118/24/20118/24/2011 8:41:31 AMAPASS
Concrete encased electrode Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok backfill concrete encased electrode
ELE11-01898 Final8/23/20118/24/20118/24/2011 7:57:13 AMAPASS
Final and Cover Inspection Phone #: ###-#### >> Inspection requested via web by Brandon Sorensen corrections made, ok final, signed card
ELE11-00404 ELE-Aging Inspection8/24/20118/24/20118/24/2011 7:17:26 AM DONE
see final
ELE11-00404 Final8/24/20118/24/20118/24/2011 7:17:13 AMAPASS
ok final