Inspections for the day of: Wednesday, August 24, 2011.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01001 Final8/23/20118/24/20118/24/2011 4:17:22 PMPPASS
requests after 4, he will call inspector//Todd Phone #: ###-#### final ok
ELE11-00098 Final8/24/20118/24/20118/24/2011 3:49:55 PMPPASS
service upgrade and a/c circuit final ok
ELE11-01963 Electrical Rough-In8/24/20118/24/20118/24/2011 3:22:51 PMPFAIL
Trench covered before inspection, contractor dug up two two locations. NEC 3004 NM cable shall be stapled within 12 inches of an receptacle or light box. NEC 334.4 (A) (B) Edge of bored holes and NM cable shall be 1 1/4 from edge of framimg member. NEC 334.25 Bending radius The radius of the curve of the inner edge of any bend during or after installation shall not be less than five times the diameter of the cable
ELE11-01963 Conference8/24/20118/24/20118/24/2011 3:01:46 PMPDONE
Talked with general contractor-home owner not available-wiring allready installed before conference meeting. some electrical corrections needed before covering
ELE11-01953 Rough-In Permanent Service8/24/20118/24/20118/24/2011 1:40:13 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman rough-in p/s o/h rec ok
ELE11-01878 Electrical Rough-In8/24/20118/24/20118/24/2011 1:05:59 PMPPASS
OK to cover underground >> Inspection requested via web by chris green rough-in ok cover underground 3/4 pvc piping
ELE11-01414 Final8/24/20118/24/20118/24/2011 12:40:04 PMPPASS
TOM Phone #: ###-#### final ok
ELE11-01955 Electrical Rough-In8/24/20118/24/20118/24/2011 12:16:49 PMPPASS
pat Phone #: ###-#### rough-in ok cover office addition
ELE11-01942 Conference8/22/20118/24/20118/24/2011 10:33:09 AMADONE
Bob Scott Phone #: ###-#### Discuss with home owner wiring methods for outdoor kitchen, GFCI protection, Listed weather resistance receptacles, inuse covers.
ELE11-01765 Electrical Rough-In8/23/20118/24/20118/24/2011 9:36:08 AMAPASS
Call for access---Dave Phone #: ###-#### rough-in ok cover hall bathroom
ELE11-01952 Electrical Rough-In8/23/20118/24/20118/24/2011 9:20:52 AMAPASS
inspect wiring in bonus room above garage. Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS rough-in ok cover
ELE11-01835 Final8/23/20118/24/20118/24/2011 9:05:15 AMAPASS
This was a simple disconnect and reconnect. Thank you. Phone #: ###-#### >> Inspection requested via web by Brad Girard final ok
ELE11-01849 Final8/23/20118/24/20118/24/2011 9:03:18 AMAPASS
This was just a disconnect and reconnect. Thank you. Phone #: ###-#### >> Inspection requested via web by Brad Girard final ok
ELE11-00405 ELE-Aging Inspection8/24/20118/24/20118/24/2011 7:46:39 AM PASS
srill under construction