Inspections for the day of: Wednesday, August 24, 2016.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-03831 Rough-in8/24/20168/24/20168/24/2016 4:32:22 PMPPASS
Clint ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC16-01736 Rough-in8/24/20168/24/20168/24/2016 3:40:33 PMPPASS
Will Phone #: ###-####
3rd floor ok to cover
MEC16-03808 Final8/23/20168/24/20168/24/2016 2:45:58 PMPPART
Mid afternoon inspection please
Installer: Jarod ###-####
Thank you
Phone #: ###-#### Inspection requested via web by Dustin Rich
no fan
MEC16-03667 Rough-in8/24/20168/24/20168/24/2016 2:32:13 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
1st floor bedroom transfer needs to be secured.
2nd floor dryer vent needs nailplates
MEC16-03667 Pressure Test8/24/20168/24/20168/24/2016 2:30:56 PMPPART
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
20lb gas pass
need to witness flue pressure tests
MEC16-03794 Rough-in8/24/20168/24/20168/24/2016 2:04:08 PMPFAIL
Re-inspection of the rough in. There are two Man J''s on site, one in the doc holder of the furnace, and one clipped to the plans. Phone #: ###-#### Inspection requested via web by Frank Marturello
kitchen makeup air cannot come off roof
MEC16-02602 Final8/24/20168/24/20168/24/2016 1:47:33 PMPPASS
Access #5296 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
MEC16-03596 Rough-in8/24/20168/24/20168/24/2016 1:34:55 PMPFAIL
Oleg Phone #: ###-####-
need to run duct in garage per manual j
all garage penatrations need to be 26 gage mtl and fire caulked.
cannot have wire in a return plenum
MEC16-00420 Mec-Aging Inspection8/24/20168/24/20168/24/2016 11:23:07 AM CANC
MEC16-00420 DOC - Permit Finaled8/24/20168/24/20168/24/2016 11:22:57 AMPPASS
MEC15-05293 Mec-Aging Inspection8/24/20168/24/20168/24/2016 11:22:02 AM PEND
MEC16-00431 Mec-Aging Inspection8/24/20168/24/20168/24/2016 11:21:15 AM PEND
MEC16-03836 Rough-in8/23/20168/24/20168/24/2016 11:18:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
MEC16-03702 Rough-in8/23/20168/24/20168/24/2016 10:24:22 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves,
fans not installed, need ladder on site to check equipment
MEC16-03702 Pressure Test8/23/20168/24/20168/24/2016 10:22:42 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves-
gas pressure gauge didnt zero out,
MEC16-02543 Pressure Test8/23/20168/24/20168/24/2016 9:59:55 AMAPASS
4th Floor in Mechanical Room gas pressure test.
Any questions call Tom ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann-
20lb gas
MEC15-05739 Rough-in8/24/20168/24/20168/24/2016 9:46:14 AMAFAIL
OK for cover mechanical shaft 3rd-6th floor. Fire Dampers 3rd-6th floor. Phone #: ###-#### Inspection requested via web by Melissa Kaae
fire dampers need to be installed per manufactures instructions
MEC16-01756 Final8/23/20168/24/20168/24/2016 8:59:40 AMAPASS
Please inspect before 9 AM. Joe has to leave for work at 9:30.. Joe Bonawitt ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC16-02363 Final8/23/20168/24/20168/24/2016 8:46:16 AMAPASS
CODE: 0713 Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-03738 Pressure Test8/23/20168/24/20168/24/2016 7:32:13 AMACANC
Phone #: ###-#### >> Inspection requested via web by John Horsfall Inspection cancelled from web by: John Horsfall