Inspections for the day of: Friday, August 24, 2018.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrandon Shaw
TitleBLD-COM/RES INSPECTOR
Phone #208-954-9358
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-01654 BLD-Framing/Rough-in8/24/20188/24/20188/24/2018 5:03:44 PMPFAIL
Need Mech rough in...
Air/foam seal not done at time of inspection
As per conversation- finish lateral bracing for trusses and squash block for column fransfer from second story to foundation...
No other issues
BLD18-01654 BLD-Wall Bracing8/24/20188/24/20188/24/2018 5:00:15 PMPPART
Exterior only- OK to cover

Interior shear to be approved/revised by Engineer of record
BLD17-04609 BLD-Final8/24/20188/24/20188/24/2018 4:58:51 PMPPASS
Final Phone #: ###-#### Inspection requested via web by Joshua Adams
BLD17-04609 DOC - Permit Finaled8/24/20188/24/20188/24/2018 4:58:42 PMPPASS
BLD18-00494 BLD-Foundation8/24/20188/24/20188/24/2018 4:58:35 PMPPASS
Trash enclosure and screen wall
BLD18-00615 BLD-Framing/Rough-in8/24/20188/24/20188/24/2018 4:57:53 PMPPART
Per plans, 1/2" anchor bolts to be secured- 2"x2" washers and nuts
Add missing anchor bolts to ends of sill plates
See red paint
OK to insulate
BLD18-00967 BLD-Wall Bracing8/23/20188/24/20188/24/2018 4:54:40 PMAFAIL
Hold downs and floor to floor HD/Straps to be as per plans/locations- See pgs S2.0- 2.2 detail 10
See red paint

Do not cover exterior
BLD18-00513 BLD-Wall Bracing8/24/20188/24/20188/24/2018 1:14:29 PMPPASS
shear // migeual Phone #: ###-####
BLD18-01623 BLD-Final8/23/20188/24/20188/24/2018 11:17:16 AMAPASS
Phone #: 2084125269 >> Inspection requested via mobile web by Anthony Boyd
BLD18-01623 DOC - Permit Finaled8/24/20188/24/20188/24/2018 11:17:07 AMPPASS
BLD18-01430 BLD-Wall Bracing8/24/20188/24/20188/24/2018 11:12:36 AMAPASS
BLD18-01430 BLD-Other8/23/20188/24/20188/24/2018 11:12:24 AMAPASS
sofit // Les Phone #: ###-####
BLD18-01430 BLD-Framing/Rough-in8/23/20188/24/20188/24/2018 11:12:11 AMANR
Les Phone #: ###-####
BLD18-00967 BLD-Other8/23/20188/24/20188/24/2018 11:11:21 AMAPEND
Pending wall bracing corrections

Do not cover exterior
BLD18-00638 BLD-Aging Inspection8/24/20188/24/20188/24/2018 8:01:20 AM DEFR
Work in progress
BLD18-00615 BLD-Framing/Rough-in8/23/20188/24/20188/24/2018 7:26:48 AMACANC
Phone #: ###-#### >> Inspection requested via web by Clint Wall Inspection cancelled from web by: Clint Wall
BLD17-03779 BLD-Blower Door Test Results8/23/20188/24/20188/24/2018 6:28:10 AMACANC
Phone #: ###-#### >> Inspection requested via web by Clint Wall Inspection cancelled from web by: Clint Wall
BLD17-03779 BLD-Final8/23/20188/24/20188/24/2018 6:28:05 AMACANC
Phone #: ###-#### >> Inspection requested via web by Clint Wall Inspection cancelled from web by: Clint Wall