MEC18-03335
| Final | 8/23/2018 | 8/24/2018 | 8/24/2018 4:03:29 PM | P | NH |
|
|
This guy is only available from 3 - 3:30. Don Davidson ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - called Don and tried to leave a message and rang the door bell and no one answered.
|
MEC18-04147
| Final | 8/24/2018 | 8/24/2018 | 8/24/2018 3:43:13 PM | P | PASS |
|
|
LATE P.M. FINAL PLEASE INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace co ok
|
MEC18-04004
| Final | 8/20/2018 | 8/24/2018 | 8/24/2018 3:14:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace ac coil co ok
|
MEC18-04144
| DOC - Permit Finaled | 8/24/2018 | 8/24/2018 | 8/24/2018 2:56:35 PM | P | PASS |
|
|
|
MEC18-04144
| Rough-in | 8/23/2018 | 8/24/2018 | 8/24/2018 2:55:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige- R/I cover ok
|
MEC18-03990
| Final | 8/23/2018 | 8/24/2018 | 8/24/2018 2:25:49 PM | P | FAIL |
|
|
please call when you are on your way so we can let you in the house. Phone #: ###-#### Inspection requested via web by Dan McFate - need drip leg in gas line furnace- line set insulation needs fixed about furnace
|
MEC18-02864
| Final | 8/24/2018 | 8/24/2018 | 8/24/2018 2:00:57 PM | P | NR |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- not ready
|
MEC18-04122
| Final | 8/22/2018 | 8/24/2018 | 8/24/2018 1:46:07 PM | P | FAIL |
|
|
Please inspect in the PM and call on way: Maddie ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss -5lb flue pressure test was under 5lb
|
MEC18-03812
| Rough-in | 8/23/2018 | 8/24/2018 | 8/24/2018 1:21:11 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - line set insulation has rips in the attic and the line set doesnt penetrate the exterior wall - duct seal at furnace - exhaust fans need duct seal with tape( downstairs) - need nail plate upstairs on exhaust in wall - need to see a 5lb flue test -20lb gas pressure gauge would not zero - water heater flue on the roof needs support
|
MEC18-03812
| Pressure Test | 8/23/2018 | 8/24/2018 | 8/24/2018 1:18:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gauge wont zero - need to see a 5lb flue test
|
MEC18-04072
| Final | 8/22/2018 | 8/24/2018 | 8/24/2018 11:22:57 AM | A | FAIL |
|
|
Final. Gas fireplace insert. Arlin Gomm is homeowner/point of contact Phone #: ###-#### Inspection requested via web by Sheldon Lebow - need a sleeve on gas line through fireplace side wall- eletrical installed for fireplace is in violation of code- need to hire a certified electrical contractor to installed per code requirements
|
MEC17-04167
| Mec-Aging Inspection | 8/24/2018 | 8/24/2018 | 8/24/2018 11:18:03 AM | | DONE |
|
|
called pipe ko and left a message about mec aging permit
|
MEC18-02078
| Final | 8/24/2018 | 8/24/2018 | 8/24/2018 11:14:28 AM | A | PASS |
|
|
IT room in airport final ok
|
MEC18-02078
| Rough-in | 8/22/2018 | 8/24/2018 | 8/24/2018 11:13:35 AM | A | PASS |
|
|
rough in - call mark Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok
|
MEC18-04064
| Final | 8/22/2018 | 8/24/2018 | 8/24/2018 10:24:12 AM | A | PASS |
|
|
Please call prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace ac coil co ok
|
MEC18-02864
| Rough-in | 8/23/2018 | 8/24/2018 | 8/24/2018 10:08:05 AM | A | PASS |
|
|
flue re-inspect Phone #: ###-#### Inspection requested via web by Brandon Sorensen - unit number 7 5 lb flue test ok -still need to see condensates done by others - need to see hard lid access doors by others - line sets on roof need supports and line set penentrations need sealed on roof - all this for a final
|
MEC18-03723
| Final | 8/23/2018 | 8/24/2018 | 8/24/2018 9:35:18 AM | A | PASS |
|
|
early as possible please Phone #: ###-#### Inspection requested via web by fritz ramisch
|
MEC18-03520
| Final | 8/24/2018 | 8/24/2018 | 8/24/2018 9:13:04 AM | P | FAIL |
|
|
furnace ac coil -need to add A/C to permit - need to see 5lb flue pressure test -need to check furnace clearances to closet door based on manufacturers specs -need to also check combustion air for furnace whether its coming from the crawl and attic or if you need to install a two pipe system -
|