Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01193 ELE-Aging Inspection8/25/20058/25/20058/26/2005 9:39:24 AM DONE
ELE05-02128 Final8/24/20058/25/20058/25/2005 11:14:28 AMAFAIL
Contact is Seth; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen cor. posted called 210.52(C)(1&5) needs 2ft 4 ft spacing for peninsular counter, 410.8 clearence closet lights, 314.16 box fill end of counter and no open wiring
ELE05-03060 Permanent Service8/25/20058/25/20058/25/2005 10:36:52 AMPCANC
darrell or ###-####; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Inspection cancelled from web by: Barbara Moore
ELE05-03016 Rough-In Permanent Service8/24/20058/25/20058/25/2005 10:35:42 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: William Zerfas see added p/s cor. posted did not correct all violations, 110.14(B) loose grd connections, 300.4 nail plates and 11/4" called
ELE05-03110 Electrical Rough-In8/25/20058/25/20058/25/2005 10:13:49 AMPPART
trenching inspection///roger ###-#### u/g for post light ok
ELE05-02976 Rough-In Permanent Service8/24/20058/25/20058/25/2005 9:59:45 AMAFAIL
Scheduled by a contractor via Hello! on 8/24/2005 at 4:51:09 PM. Contact: ###-####. cor. do not cover posted called 300.4(A)(1)&(D), 250.122 needs #12 equip grd for 20 amp circuit, 110.3&314.17 replace broken box in kit., and all outside recept boxes with broken clamps, protect meterbase
ELE05-03022 Electrical Rough-In8/25/20058/25/20058/25/2005 9:22:34 AMPPART
Scheduled by a contractor via Hello! on 8/25/2005 at 8:23:37 AM. area seperation wall ok
ELE05-02929 Electrical Rough-In8/24/20058/25/20058/25/2005 9:20:10 AMAPART
dan ###-#### grid ceilings ok
ELE05-02894 Final8/24/20058/25/20058/25/2005 8:23:18 AMAPASS
john campbell; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok needs gfci for rest rms , grd jbox, contractor on site he will correct no card at job site
ELE05-02929 Permanent Service8/25/20058/25/20058/25/2005 12:00:00 AMAPASS
dan ###-#### p/s u/g new for meter ok
ELE05-03016 Permanent Service8/25/20058/25/20058/25/2005 12:00:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: William Zerfas p/s u/g new ok