Inspections for the day of: Friday, August 25, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03141 Electrical Rough-In8/25/20068/25/20068/25/2006 4:09:02 PMPPASS
3 room addition Internet Inspection Request from: Rowdy Monroe called contr to add recpts, ric ok
ELE06-03182 Electrical Rough-In8/25/20068/25/20068/25/2006 3:47:04 PMPPART
adam Note: partial cover inspection; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles soffit ok to cover
ELE06-03185 Electrical Rough-In8/25/20068/25/20068/25/2006 3:08:00 PMPCANC
need U/G inspection for cover. conduit will be installed by 1:30pm. if possible, please inspect after, thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH talked to elect, he asked to cancel said wanted shop to call for later inspection
ELE06-03166 Rough-In Permanent Service8/25/20068/25/20068/25/2006 2:48:01 PMPFAIL
gary; Phone #: ###-#### Internet Inspection Request from: Darla Downs called, left corr notice, nec 408.4 circuit directory shall be complete, concise , and explanatory for each circuit, 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member, 406.5,110.12(C) recpt faceplate shall cover opening at recpt and no broken parts shall be used, 334.30 nm cable shall be supported within 12" of flex under bench, 110.26 access and working space shall be provided at panel, BCC no violations shall be retained(open splices over bench),strap flex into panel Note: ok to cover u/g, looked at feeder from in house, it is ok
ELE06-02906 Electrical Rough-In8/25/20068/25/20068/25/2006 1:22:04 PMPPASS
Craig; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr made, ric ok
ELE06-03171 Conference8/24/20068/25/20068/25/2006 11:53:39 AMADONE
curtis - call prior to meet there; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley told contr u/g shall be inspected and concrete encased gec shall be supplied
ELE06-02496 Final8/24/20068/25/20068/25/2006 10:52:00 AMAFAIL
Internet Inspection Request from: Rowdy Monroe called left corr notice, nec 422.31(B) disconnect shall be supplied for heater, 110.3 gfci left of stove shall operate,BCC access shall be provided inside panel
ELE06-02668 Electrical Rough-In8/24/20068/25/20068/25/2006 10:32:23 AMAPART
eric - exterior conduit insp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley u/g from street side pole base to sidewalk only ok to cover, cnd going to bldg has 3 90s from west pole base and is just under sidewalk bldg side
ELE06-03109 Rough-In Permanent Service8/24/20068/25/20068/25/2006 9:59:35 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok, p/s u/g n ok
ELE06-03179 Electrical Rough-In8/24/20068/25/20068/25/2006 9:54:12 AMAFAIL
jeremy; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called contr, left message, nec 517.13(A) metal raceways shall be provided for grounding purposes, BCC no violations shall be retained, Note: partial corrections until rest of equipment opened up
ELE06-02477 Final8/25/20068/25/20068/25/2006 9:02:28 AMAPASS
Scheduled by a contractor via Hello! on 8/25/2006 at 5:28:09 AM. Contact: ###-####. ok to final
ELE06-01187 Electrical Rough-In8/24/20068/25/20068/25/2006 8:36:02 AMAFAIL
Area above the lay-in ceiling inspected so ceiling tile may be installed Call John at ###-####; Phone #: ###-#### Internet Inspection Request from: Celinda Winters called contr, left corr notice, BCC fixtures shall have 2 struct support wires and no low voltage wires shall be on grid. Made corr notice to contr and to owner
ELE06-02613 Electrical Rough-In8/24/20068/25/20068/25/2006 8:12:53 AMAPART
this is for the 1st floor, any questions please call James Lingelbaugh; Phone #: ###-#### Internet Inspection Request from: Jeff Radford mezzanine walls only ok to cover
ELE06-03178 Electrical Rough-In8/24/20068/25/20068/25/2006 8:12:01 AMAPART
any questions please call James Lingelbaugh; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to cover u/g