Inspections for the day of: Wednesday, August 26, 1998.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Sly
TitleBLD-COM/RES INSPECTOR
Phone #794-9465
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD98-01016 INSP - Energy code compliance8/26/19988/26/19988/26/1998 12:00:00 AM PASS
/ / 316 -
BLD98-01403 INSP - Energy code compliance8/26/19988/26/19988/26/1998 12:00:00 AM PASS
/ / 316 -
BLD98-00980 INSP - Letter of compliance8/26/19988/26/19988/26/1998 12:00:00 AM PASS
/ / 316 - C/C # 015719
BLD98-00980 INSP - Letter of compliance8/26/19988/26/19988/26/1998 12:00:00 AM PASS
/ / 316 - C/C # 015719
BLD98-02044 INSP - Wall cover8/25/19988/26/19988/26/1998 12:00:00 AMAPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3879554].
BLD98-02362 INSP - Foundation8/25/19988/26/19988/26/1998 12:00:00 AMAFAIL
08/26/98 316 - No one or appr plan on site..Pour W/O..foot width,height,
BLD98-02552 INSP - Foundation8/25/19988/26/19988/26/1998 12:00:00 AMAFAIL
08/26/98 316 - Pour W/O..Early start..Foot width, height, soil OK ..setb
BLD98-01403 INSP - Framing/Rough-in8/25/19988/26/19988/26/1998 12:00:00 AMAPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3857310].
BLD98-01534 INSP - Framing/Rough-in8/25/19988/26/19988/26/1998 12:00:00 AMAPART
08/26/98 316 - Shear wall OK.....
BLD98-01668 INSP - Foundation8/25/19988/26/19988/26/1998 12:00:00 AMPFAIL
08/26/98 316 - Pour W/O..Foot width, soil, height OK...Setbks appear OK.
BLD98-01700 INSP - Framing/Rough-in8/26/19988/26/19988/26/1998 12:00:00 AMPFAIL
08/26/98 316 - C/N...Need to complete all req nailing of framing per Eng
BLD98-01881 INSP - Framing/Rough-in8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3716727].
BLD98-01016 INSP - Framing/Rough-in8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - bruce ###-####
BLD98-01141 INSP - Energy code compliance8/25/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3787771].
BLD98-01141 INSP - Framing/Rough-in8/25/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3787771].
MEC98-02299 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - joe ###-####
MEC98-02299 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - joe ###-####
MEC98-02404 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3434446].
MEC98-02404 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - Scheduled by Hello!. Contact phone is [3434446].
MEC98-02720 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPART
08/26/98 316 - f/p Rough in insp only ....OK
MEC98-02720 INSP - Final8/26/19988/26/19988/26/1998 12:00:00 AMPPART
08/26/98 316 - f/p Rough in insp only ....OK
MEC98-02757 INSP - Framing/ Rough-in8/25/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - T # 031159
BLD98-00980 INSP - Final8/25/19988/26/19988/26/1998 12:00:00 AMPPASS
08/26/98 316 - C/C # 015719
MEC98-02404 INSP - Final8/25/19988/26/19988/25/1998 12:00:00 AMACANC
Scheduled by Hello!. Contact phone is [3434446]. Cancelled by Hello! (Last update by [HLO]). Contact: [3434446].
MEC98-02404 INSP - Final8/25/19988/26/19988/25/1998 12:00:00 AMACANC