Inspections for the day of: Wednesday, August 26, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00099 ELE-Aging Inspection8/26/20158/26/20158/27/2015 2:00:56 PM DONE
Owner refusing to comply
ELE15-02623 Permanent Service8/25/20158/26/20158/26/2015 2:20:44 PMPPASS
Chad Peck, is contact ###-####. thank you Phone #: ###-#### Inspection requested via web by Debby Pierce Future work to include underground to RV pad and shop. p/s o/h rec ok
ELE15-02691 Electrical Rough-In8/26/20158/26/20158/26/2015 2:10:04 PMPCANC
Need ok for power to be restored Phone #: ###-#### Inspection requested via web by Randy Fletcher Needed permanent service inspection
ELE15-02691 Permanent Service8/26/20158/26/20158/26/2015 1:55:41 PMPPASS
Need ok for power to be restored Phone #: ###-#### Inspection requested via web by Randy Fletcher Range to be refed from old hot tub feed on exterior of house. Old interior panel shall remain accessible. p/s o/h rec ok
ELE15-02160 Electrical Rough-In8/26/20158/26/20158/26/2015 1:35:55 PMPPASS
Sam Phone #: ###-#### Check on final back-fed main secured in place by additional means as per 408.36(D). Detached garage rough in ok cover
ELE15-01424 Final8/25/20158/26/20158/26/2015 12:56:20 PMPPASS
Inspection requested via web by Dana Vance UL listing and disconnecting means confirmed. Final ok
ELE15-00732 Final8/25/20158/26/20158/26/2015 12:31:25 PMPPASS
Inspection requested via web by Dana Vance UL listing and disconnecting means confirmed. Final ok
MIS15-00222 ELE-Conference8/26/20158/26/20158/26/2015 12:22:18 PMPCANC
Elaina- ###-#### Wrong day requested.
MIS15-00222 ELE-Final8/26/20158/26/20158/26/2015 12:19:21 PMPFAIL
Elaina// please call before///Electrical permit for permanent occupancy approval. NO electrical work was done. Phone #: ###-#### 210.8- All receptacle outlets located within 6' of a sink shall have GFCI protection. 406.12-All receptacle outlets located in classroom areas shall be tamper resistant type. Informed that Enterprise Electric installed wiring for exit signs however unable to locate permit for work. Preschool director stated and provided documentation refering to an exemption from permitting due to non- profit. Forwarded to supervisor to review and inform me how to proceed with permitting.
ELE14-03020 Final8/25/20158/26/20158/26/2015 11:03:08 AMPFAIL
Inspection requested via web by Dana Vance 300.15- A box shall be installed at each outlet point for MC cable. 4 light openings above sign on front of tenant space.
ELE15-02686 Electrical Rough-In8/25/20158/26/20158/26/2015 10:45:28 AMAPASS
Mucho Phone #: ###-#### New bathroom upstairs in rear of house. Rough in ok cover
ELE15-02274 Permanent Service8/26/20158/26/20158/26/2015 10:11:10 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov p/s u/g n ok
ELE15-02711 Electrical Rough-In8/26/20158/26/20158/26/2015 9:48:48 AMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 1 of 2 permits for space. Wall rough in ok cover
ELE15-02695 Electrical Rough-In8/25/20158/26/20158/26/2015 9:44:45 AMAPASS
BOB THOMAS Phone #: ###-#### Inspection requested via web by Kerri Hamilton 1 of 2 permits for space. Wall rough in ok cover
ELE15-02334 Electrical Rough-In8/25/20158/26/20158/26/2015 9:24:08 AMAPASS
Underground bonding-pool Phone #: ###-#### Inspection requested via web by Kotton Corder Perimeter bond rough in ok cover
ELE15-02343 Final8/26/20158/26/20158/26/2015 9:06:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe Final ok
ELE15-02482 Electrical Rough-In8/25/20158/26/20158/26/2015 8:44:53 AMAPART
Wall inspection Phone #: ###-#### Inspection requested via web by Thomas Jenkins 210.62- At least one 125 volt 15 or 20 amp rated receptacle outlet shall be installed within 18" of top of show window for each 12 linear ft. or major fraction thereof of show window area measured horizontally. Interior walls only rough in ok cover