ELE16-01838
| Electrical Rough-In | 8/25/2016 | 8/26/2016 | 8/26/2016 3:33:37 PM | P | PASS |
|
|
Headquarters- Stack 1 East offices on level 2 and 4, Level 9 rooms #915 and #929, and Annex Level 5 hard lid ceilings. Phone #: ###-#### Inspection requested via web by Brandon Robinson Floors 2, 4, 6 east offices grid. Sky bridge hardlids floors 4, and 5. Annex 4th floor halls north stair, east, and south stair areas ceiling foam installation. Annex 5th floor elevator hall to west ceilings. Annex sensory kitchen #5 ceiling. Annex 5th floor ladies bathroom ceiling. Areas noted rough in ok cover 300.15- Annex 5th floor mens bath lid access shall be available for HVAC unit located in ceiling. Door will not open to 90 degree angle minimum and access very limited.
|
ELE13-01291
| Electrical Rough-In | 8/26/2016 | 8/26/2016 | 8/26/2016 3:23:31 PM | P | NR |
|
|
site underground northwest corner. call Frank. Phone #: ###-#### Inspection requested via web by Brandon Robinson Will recall
|
ELE15-01348
| Electrical Rough-In | 8/26/2016 | 8/26/2016 | 8/26/2016 3:23:06 PM | P | PASS |
|
|
C;S Room # 104,105 Walls Walls North side Room 100, 123 Phone #: ###-#### Inspection requested via web by Tom Betty Area 100 corridor north walls and columns 06, 07, 08. 09 column not ready. Area 123 north wall and column 011 west side only. Bathrooms 104, 105 walls only. Areas noted rough in ok cover
|
ELE16-02636
| Electrical Rough-In | 8/25/2016 | 8/26/2016 | 8/26/2016 1:34:35 PM | A | FAIL |
|
|
Dean Phone #: ###-#### Area has changed. Kitchen remodel, cabinets change litlle bit, added pantry, master bed and bath. Owner pulled permit has an individual helping who is not family. Friend denied helping but answered all questions. Complained about being told make up not required to all switch boxes, or 6" of useable wire available at each box. Informed owner takes full responcibility for wiring and its not our job to inform them of any or all codes required. 210.11(C)(1)- All receptacles serving counter top areas shall be fed from small appliance 20 amp circuit described in 210.52. 210.52- All kitchen counter top areas 12" or wider shall have a receptacle installed. Left of range. 300.14- At each switch, receptacle, or outlet a minimum of 6" of useable wire shall be available. 300.15- All junctions shall be installed in an accessible location. Found junction boxes that were to be buried by drywall. 1 front bed, 1 master bed entrance, 1 master vanity. 334.12- Existing range wire exits wall cavity and enters box screwed to floor. NM cable shall not be installed where subjent to physical damage. BCC 4-05-32 Code violations not to be retained.
|
ELE16-02788
| Electrical Rough-In | 8/25/2016 | 8/26/2016 | 8/26/2016 10:52:34 AM | A | NH |
|
|
access 0222, repair upstairs bedroom and garage curcuits Phone #: ###-#### Inspection requested via web by David Nelson Access code did not work. Will recall
|
ELE13-02399
| ELE-Aging Inspection | 8/26/2016 | 8/26/2016 | 8/26/2016 10:22:55 AM | | PASS |
|
|
Work completed under permit # ELE13-02431
|
ELE13-02399
| Final | 8/26/2016 | 8/26/2016 | 8/26/2016 9:50:42 AM | P | PASS |
|
|
Work completed under permit # ELE13-02431. Final ok
|
ELE16-00507
| Permanent Service | 8/25/2016 | 8/26/2016 | 8/26/2016 9:47:59 AM | A | PASS |
|
|
Seth Phone #: ###-#### Meyers cabinet south entrance p/s u/g n ok
|
ELE16-00594
| Final | 8/25/2016 | 8/26/2016 | 8/26/2016 9:31:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sharon Hurd Final ok
|
ELE16-02151
| Rough-In Permanent Service | 8/25/2016 | 8/26/2016 | 8/26/2016 9:19:36 AM | A | PASS |
|
|
Larry Phone #: ###-#### Service rough in ok p/s u/g n ok
|
ELE16-02577
| Final | 8/25/2016 | 8/26/2016 | 8/26/2016 8:35:37 AM | A | CANC |
|
|
Early as possible, please call ahead for access - Ted Phone #: ###-#### Needed permanent service inspection
|
ELE16-02577
| Permanent Service | 8/26/2016 | 8/26/2016 | 8/26/2016 8:34:46 AM | P | PASS |
|
|
Early as possible, please call ahead for access - Ted Phone #: ###-#### 250.53(A)- A single underground water pipe shall be supplemented by an additional rod. p/s o/h rec ok
|
ELE16-02788
| Electrical Rough-In | 8/25/2016 | 8/26/2016 | 8/25/2016 2:30:14 PM | A | CANC |
|
|
repair upstairs bedroom and garage circuits Phone #: ###-#### >> Inspection requested via web by David Nelson Inspection cancelled from web by: David Nelson
|