BLD14-03070
| BLD-Wall cover | 8/26/2016 | 8/26/2016 | 8/26/2016 4:55:10 PM | P | PASS |
|
|
Cody Phone #: ###-####, SOuth units, 2nd floor fur downs.
|
BLD16-02644
| BLD-Wall Bracing | 8/25/2016 | 8/26/2016 | 8/26/2016 3:28:11 PM | P | PASS |
|
|
Shear // John Phone #: ###-####
|
BLD16-02629
| BLD-Other | 8/25/2016 | 8/26/2016 | 8/26/2016 3:17:48 PM | P | NR |
|
|
Phone #: ###-#### Inspection requested via web by Dean Rooke
|
BLD15-03208
| BLD-Framing/Rough-in | 8/24/2016 | 8/26/2016 | 8/26/2016 2:54:32 PM | P | FAIL |
|
|
David Phone #: ###-####. Strap LVL at garage for portal frame. Strap double top plate splice i garage at either sides of opening to mudroom. Complete lateral bracing on T01, T03, T06, T08, trusses. Missed interior bearing points on 2 T02 trusses. Provide fix from truss engineer. Strap double top plates LVL in living room. Add additional stud to both ends of LVL in living room and nail or strap. Provide header at openong under T04 truss interior bearing point. Correction notice posted. Ok to insulate.
|
BLD16-02005
| BLD-Final | 8/25/2016 | 8/26/2016 | 8/26/2016 1:40:59 PM | P | PASS |
|
|
Cecil Phone #: ###-####
|
BLD16-02005
| DOC - Permit Finaled | 8/26/2016 | 8/26/2016 | 8/26/2016 1:40:47 PM | P | PASS |
|
|
|
BLD16-03124
| BLD-Conference | 8/26/2016 | 8/26/2016 | 8/26/2016 1:40:28 PM | P | DONE |
|
|
need final on roof Phone #: ###-#### Inspection requested via web by Chris Howell
|
BLD16-03124
| DOC - Permit Finaled | 8/26/2016 | 8/26/2016 | 8/26/2016 1:40:14 PM | P | PASS |
|
|
All work appeared to be done in accordance with local codes and ordinances.
|
BLD16-01523
| BLD-Framing/Rough-in | 8/26/2016 | 8/26/2016 | 8/26/2016 11:11:42 AM | A | PASS |
|
|
Building is restricted access. Please call 45 minutes prior so I can guarantee access. Jim ###-#### Phone #: ###-#### Inspection requested via web by James Thompson. Interior wood framed walls ok.
|
BLD16-02719
| BLD-Wall Bracing | 8/25/2016 | 8/26/2016 | 8/26/2016 9:41:18 AM | A | PASS |
|
|
Zane Phone #: ###-####
|