Inspections for the day of: Wednesday, August 27, 2003.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE03-02628 Electrical Rough-In8/26/20038/27/20038/27/2003 12:00:00 AMAFAIL
sandy; Phone #: ###-#### Internet Inspection Request from: Barbara Moore called left message needs to add box extensions and 300.4 11/4 for flex 8/27/2003 8:54:55 AM
ELE03-02644 Electrical Rough-In8/26/20038/27/20038/27/2003 12:00:00 AMAPASS
###-#### r/i ok 8/27/2003 10:26:23 AM
ELE03-02315 Final8/26/20038/27/20038/27/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 8/26/2003 at 2:51:50 PM. Contact: ###-####. ok 8/27/2003 9:22:39 AM
ELE02-01916 Final8/26/20038/27/20038/27/2003 12:00:00 AMANR
andy--call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie see added p/s
8/27/2003 10:43:58 AM
ELE03-02634 Electrical Rough-In8/26/20038/27/20038/27/2003 12:00:00 AMAPART
###-#### russ//20' copper ground wire ok 8/27/2003 8:30:36 AM
ELE03-02635 Electrical Rough-In8/26/20038/27/20038/27/2003 12:00:00 AMAPART
###-#### russ//20' copper ground wire ok 8/27/2003 8:30:29 AM
ELE02-01916 Permanent Service8/27/20038/27/20038/27/2003 12:00:00 AMAPASS
p/s o/h rec. ok
ELE03-02342 Final8/27/20038/27/20038/27/2003 12:00:00 AMPNR
john; Phone #: ###-#### Internet Inspection Request from: Annette Moore contractor will reschedule 8/27/2003 1:32:53 PM
ELE03-02528 Permanent Service8/27/20038/27/20038/27/2003 12:00:00 AMPPASS
p/s u/g new ok
ELE03-02528 Electrical Rough-In8/27/20038/27/20038/27/2003 12:00:00 AMPPART
Contact: Bill Hines; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
r/i east half of duplex ok see added p/s 8/27/2003 4:05:40 PM
ELE03-00057 Electrical Rough-In8/27/20038/27/20038/27/2003 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 8/27/2003 at 8:15:22 AM. Contact: ###-####. ceiling and nurse areas ok print marked 8/27/2003 3:08:34 PM
ELE03-02645 Permanent Service8/27/20038/27/20038/27/2003 12:00:00 AMPFAIL
david; Phone #: ###-#### Internet Inspection Request from: Marc Lileks cor. posted met with owner 250.52(A)(1),or104(A) grd or bond water system 310.15 proper breaker size for #10, #8, needs 200 amp wire for 200 amp p/s, 250.140,142,134(A) dryer type se or 10/3, 230.24(B) service drop clearence, 408.4 label panel, hot tub shall be wired by electrical contractor remove wiring done by owner 8/27/2003 1:15:15 PM
ELE03-02524 Rough-In Permanent Service8/27/20038/27/20038/27/2003 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 8/27/2003 at 8:27:55 AM. Contact: ###-####. cor. posted called 110.3 (B) not service rated needs required grd bus kit 8/27/2003 2:06:04 PM