PLM12-02762
| PLM-Aging Inspection | 8/27/2015 | 8/27/2015 | 8/27/2015 4:13:53 PM | | PART |
|
|
Wip/ to be done in the next 60 days per phone call.
|
PLM15-02869
| Final | 8/25/2015 | 8/27/2015 | 8/27/2015 4:06:20 PM | P | FAIL |
|
|
Ready between 1-3pm. if questions call Dan @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann >1 discharge from relief valve into water heater pan is prohibited per 508.5 upc. pipe seperate to garage floor. >2 remove foil tape from flue joints.
|
PLM15-02848
| Plumbing Rough-in | 8/26/2015 | 8/27/2015 | 8/27/2015 3:44:30 PM | P | FAIL |
|
|
JOB # 18134 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes 1>DWV test failed-leaks 2> waters at upstairs lavs in unheated space.
|
PLM15-02849
| Plumbing Rough-in | 8/26/2015 | 8/27/2015 | 8/27/2015 3:43:03 PM | P | FAIL |
|
|
JOB # 18135. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes 1>DWV test fail-leaks 2>3" over dinning is not 1/4" per foot and is back graded at 90 on wall. 3>Shower trap arm exceeds 5' max length
|
PLM15-02865
| Plumbing Rough-in | 8/27/2015 | 8/27/2015 | 8/27/2015 3:11:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sean Hyten bathroom r/i in shop ok to cover
|
PLM15-02865
| Water and/or Sewer | 8/26/2015 | 8/27/2015 | 8/27/2015 3:10:47 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Sean Hyten
|
PLM15-01850
| Plumbing Rough-in | 8/27/2015 | 8/27/2015 | 8/27/2015 2:55:57 PM | P | NR |
|
|
Please Come after 3:30 Phone #: ###-#### Inspection requested via web by Erin Whiting
|
PLM15-02219
| Final | 8/26/2015 | 8/27/2015 | 8/27/2015 2:46:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM15-02904
| Water and/or Sewer | 8/27/2015 | 8/27/2015 | 8/27/2015 2:36:11 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Gregg Barney >need sprinkler backflow certified.
|
PLM15-01494
| Final | 8/27/2015 | 8/27/2015 | 8/27/2015 2:24:00 PM | P | NR |
|
|
Any questions call Rick @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann >NR no dw
|
PLM15-01492
| Final | 8/27/2015 | 8/27/2015 | 8/27/2015 2:20:59 PM | P | NR |
|
|
Any questions call Rick. Phone #: ###-#### Inspection requested via web by Stacia Haumann >nr no dw
|
PLM15-02513
| Water and/or Sewer | 8/27/2015 | 8/27/2015 | 8/27/2015 2:08:30 PM | P | PART |
|
|
Trent Phone #: ###-#### >ok to bury last section to car wash.
|
PLM15-01371
| Plumbing Rough-in | 8/27/2015 | 8/27/2015 | 8/27/2015 2:06:43 PM | P | PART |
|
|
JOB CONTACT - DAVID ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >bathrooms, manager area ok to cover
|
PLM15-02910
| DOC - Permit Finaled | 8/27/2015 | 8/27/2015 | 8/27/2015 1:19:52 PM | P | PASS |
|
|
|
PLM15-02910
| Water and/or Sewer | 8/27/2015 | 8/27/2015 | 8/27/2015 1:19:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM15-02362
| Final | 8/26/2015 | 8/27/2015 | 8/27/2015 11:02:17 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ben Davis >t&p line backgraded >Install ASSE 1070 approved tempering valve @ hand wash sinks per 413.1 UPC
|
PLM15-02302
| Final | 8/27/2015 | 8/27/2015 | 8/27/2015 10:41:04 AM | P | PASS |
|
|
1234 garage code Phone #: ###-#### Inspection requested via web by casey lattimer
|
PLM15-02864
| Water Heater Final | 8/25/2015 | 8/27/2015 | 8/27/2015 10:30:14 AM | A | PASS |
|
|
please call home owner when on the way thanks ###-#### Phone #: ###-#### Inspection requested via web by brandon winkler
|
PLM12-02762
| DOC - Permit Finaled | 8/27/2015 | 8/27/2015 | 8/27/2015 10:26:20 AM | P | PASS |
|
|
|
PLM15-02899
| Water and/or Sewer | 8/27/2015 | 8/27/2015 | 8/27/2015 10:24:33 AM | A | PASS |
|
|
if questions call Mark @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann >sewer from inside space 150 ran out to alley behind bldg and tied on downstream of incp. ok
|
PLM15-02899
| Final | 8/26/2015 | 8/27/2015 | 8/27/2015 10:23:38 AM | A | CANC |
|
|
if questions call Mark @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM15-02902
| Plumbing Rough-in | 8/27/2015 | 8/27/2015 | 8/27/2015 10:08:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jason Gale
|
PLM15-02901
| Water Heater Final | 8/26/2015 | 8/27/2015 | 8/27/2015 9:15:13 AM | A | PASS |
|
|
Call Peggy prior ###-#### Phone #: ###-#### Inspection requested via web by curtis rowe
|
PLM15-02891
| DOC - Permit Finaled | 8/27/2015 | 8/27/2015 | 8/27/2015 8:41:52 AM | P | PASS |
|
|
|
PLM15-02891
| Water and/or Sewer | 8/26/2015 | 8/27/2015 | 8/27/2015 8:41:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Vicki Tallent
|
PLM14-03532
| DOC - Permit Finaled | 8/27/2015 | 8/27/2015 | 8/27/2015 8:06:57 AM | P | PASS |
|
|
|
PLM14-03532
| PLM-Aging Inspection | 8/27/2015 | 8/27/2015 | 8/27/2015 8:06:43 AM | | PASS |
|
|
permit exp. not going to bother h/o to see a sh valve and drain.
|
PLM15-02902
| Water and/or Sewer | 8/27/2015 | 8/27/2015 | 8/27/2015 6:46:50 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Jason Gale Inspection cancelled from web by: Jason Gale
|