Inspections for the day of: Thursday, August 27, 2015.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM12-02762 PLM-Aging Inspection8/27/20158/27/20158/27/2015 4:13:53 PM PART
Wip/ to be done in the next 60 days per phone call.
PLM15-02869 Final8/25/20158/27/20158/27/2015 4:06:20 PMPFAIL
Ready between 1-3pm. if questions call Dan @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
>1 discharge from relief valve into water heater pan is prohibited per 508.5 upc. pipe seperate to garage floor.
>2 remove foil tape from flue joints.
PLM15-02848 Plumbing Rough-in8/26/20158/27/20158/27/2015 3:44:30 PMPFAIL
JOB # 18134 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
1>DWV test failed-leaks
2> waters at upstairs lavs in unheated space.
PLM15-02849 Plumbing Rough-in8/26/20158/27/20158/27/2015 3:43:03 PMPFAIL
JOB # 18135. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
1>DWV test fail-leaks
2>3" over dinning is not 1/4" per foot and is back graded at 90 on wall.
3>Shower trap arm exceeds 5' max length
PLM15-02865 Plumbing Rough-in8/27/20158/27/20158/27/2015 3:11:45 PMPPASS
Phone #: ###-#### Inspection requested via web by Sean Hyten
bathroom r/i in shop ok to cover
PLM15-02865 Water and/or Sewer8/26/20158/27/20158/27/2015 3:10:47 PMPCANC
Phone #: ###-#### Inspection requested via web by Sean Hyten
PLM15-01850 Plumbing Rough-in8/27/20158/27/20158/27/2015 2:55:57 PMPNR
Please Come after 3:30 Phone #: ###-#### Inspection requested via web by Erin Whiting
PLM15-02219 Final8/26/20158/27/20158/27/2015 2:46:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM15-02904 Water and/or Sewer8/27/20158/27/20158/27/2015 2:36:11 PMPPART
Phone #: ###-#### Inspection requested via web by Gregg Barney
>need sprinkler backflow certified.
PLM15-01494 Final8/27/20158/27/20158/27/2015 2:24:00 PMPNR
Any questions call Rick @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
>NR no dw
PLM15-01492 Final8/27/20158/27/20158/27/2015 2:20:59 PMPNR
Any questions call Rick. Phone #: ###-#### Inspection requested via web by Stacia Haumann
>nr no dw
PLM15-02513 Water and/or Sewer8/27/20158/27/20158/27/2015 2:08:30 PMPPART
Trent Phone #: ###-####
>ok to bury last section to car wash.
PLM15-01371 Plumbing Rough-in8/27/20158/27/20158/27/2015 2:06:43 PMPPART
JOB CONTACT - DAVID ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>bathrooms, manager area ok to cover
PLM15-02910 DOC - Permit Finaled8/27/20158/27/20158/27/2015 1:19:52 PMPPASS
PLM15-02910 Water and/or Sewer8/27/20158/27/20158/27/2015 1:19:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM15-02362 Final8/26/20158/27/20158/27/2015 11:02:17 AMPFAIL
Phone #: ###-#### Inspection requested via web by Ben Davis
>t&p line backgraded
>Install ASSE 1070 approved tempering valve @ hand wash sinks per 413.1 UPC
PLM15-02302 Final8/27/20158/27/20158/27/2015 10:41:04 AMPPASS
1234 garage code Phone #: ###-#### Inspection requested via web by casey lattimer
PLM15-02864 Water Heater Final8/25/20158/27/20158/27/2015 10:30:14 AMAPASS
please call home owner when on the way thanks ###-#### Phone #: ###-#### Inspection requested via web by brandon winkler
PLM12-02762 DOC - Permit Finaled8/27/20158/27/20158/27/2015 10:26:20 AMPPASS
PLM15-02899 Water and/or Sewer8/27/20158/27/20158/27/2015 10:24:33 AMAPASS
if questions call Mark @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
>sewer from inside space 150 ran out to alley behind bldg and tied on downstream of incp. ok
PLM15-02899 Final8/26/20158/27/20158/27/2015 10:23:38 AMACANC
if questions call Mark @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
PLM15-02902 Plumbing Rough-in8/27/20158/27/20158/27/2015 10:08:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Jason Gale
PLM15-02901 Water Heater Final8/26/20158/27/20158/27/2015 9:15:13 AMAPASS
Call Peggy prior ###-#### Phone #: ###-#### Inspection requested via web by curtis rowe
PLM15-02891 DOC - Permit Finaled8/27/20158/27/20158/27/2015 8:41:52 AMPPASS
PLM15-02891 Water and/or Sewer8/26/20158/27/20158/27/2015 8:41:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Vicki Tallent
PLM14-03532 DOC - Permit Finaled8/27/20158/27/20158/27/2015 8:06:57 AMPPASS
PLM14-03532 PLM-Aging Inspection8/27/20158/27/20158/27/2015 8:06:43 AM PASS
permit exp. not going to bother h/o to see a sh valve and drain.
PLM15-02902 Water and/or Sewer8/27/20158/27/20158/27/2015 6:46:50 AMACANC
Phone #: ###-#### >> Inspection requested via web by Jason Gale Inspection cancelled from web by: Jason Gale