Inspections for the day of: Tuesday, August 27, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02974 Final8/26/20198/27/20198/27/2019 3:50:03 PMPNR
VINNIE ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- per Mike general contractor debating on vented or unvented sofitt above fireplace thimble or moving thimble down 3"- will call in when issue has been corrected
MEC19-03783 Pressure Test8/27/20198/27/20198/27/2019 3:14:06 PMPPASS
Oleg Phone #: ###-####- 20lb gas pass tagged meter location- 5lb flue pass
MEC19-03783 Rough-in8/27/20198/27/20198/27/2019 3:13:36 PMPFAIL
Oleg Phone #: ###-####- need 1" clearance on b vent 2nd floor attic- need to replace smashed 4" dryer duct and fitting at attic- flex ducting needs to be installed per manufacture installation instructions- mantel installed needs moved up 1" per installation instructions and measurement is from top of appliance not deflector- see correction notice front entry window
MEC19-03418 Final8/23/20198/27/20198/27/2019 2:08:08 PMPPASS
Call Robert in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- a/c coil co ok
MEC19-03825 Final8/26/20198/27/20198/27/2019 1:11:26 PMPNH
Phone #: ###-#### Inspection requested via web by Denise Colin- no one home- no access- rang doorbell twice and knocked
MEC19-03616 Final8/26/20198/27/20198/27/2019 1:01:49 PMPPASS
Please inspect from 12-4. Contact is Brandon Cox ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC19-03652 Conference8/26/20198/27/20198/27/2019 11:09:21 AMADONE
consult with Luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- went over class 1 hood- since no labeling can be found on ul listed hood by captive aire will install to 2012 IMC-
MEC19-03637 Rough-in8/26/20198/27/20198/27/2019 10:40:08 AMAPASS
inspection is for line set and condensate drain from coil Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03637 Pressure Test8/26/20198/27/20198/27/2019 10:39:56 AMAPASS
underground gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- ok to back fill- tagged meter location
MEC19-02049 Rough-in8/26/20198/27/20198/27/2019 10:39:25 AMAPASS
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on all ducting complete- ok to insulate all remaining ducts- ok for grid- call in when registers and insulation completed
MEC19-03639 Rough-in8/26/20198/27/20198/27/2019 10:21:55 AMAPASS
inspection is for line set and condensate drain from coil Phone #: ###-#### Inspection requested via web by Joseph Profitt- R/I ok- need to support all lineset under mobile home by final
MEC19-03639 Pressure Test8/26/20198/27/20198/27/2019 10:21:22 AMAPASS
underground gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- underground gas piping ok to back fill- tagged meter location
MEC19-03641 Rough-in8/26/20198/27/20198/27/2019 10:15:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Joseph Profitt- R/I ok
MEC19-03641 Pressure Test8/26/20198/27/20198/27/2019 10:14:46 AMAPASS
underground gas line Phone #: ###-#### Inspection requested via web by Joseph Profitt- 20lb gas pass- underground gas piping ok to back fill
MEC19-03443 Rough-in8/26/20198/27/20198/27/2019 9:45:06 AMAPASS
AUSTIN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- 60lb gas test whole system from kitchen to roof ok- need documentation from engineer stating ok to use compression fitting for tie in on existing line since upgrading to 5lb system and have onsite to view by final
MEC19-03513 Final8/26/20198/27/20198/27/2019 9:19:56 AMAPASS
MORNING INSPECTION REQUESTED.. PLEASE CALL CUSTOMER SO HE CAN MEET YOU THERE. BEFORE YOU HEAD OUT. Phone #: ###-#### Inspection requested via web by Trina DeBoard- furnace a/c coil gas piping co ok
MEC19-03822 Final8/26/20198/27/20198/27/2019 9:13:30 AMAPASS
final - call brandon Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Relocation 2 sidewall exhaust fans from existing build to new building ok
MEC19-03751 Final8/22/20198/27/20198/27/2019 8:45:09 AMAPASS
Please call Rick Price prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-03738 Rough-in8/26/20198/27/20198/27/2019 8:37:20 AMAPASS
Matt Phone #: ###-####
MEC19-02356 Final8/23/20198/27/20198/27/2019 8:21:38 AMAPASS
Homeowner requests the inspection be done between 8-10am. Please call if that cannot be accommodated: Tony ###-#### Phone #: ###-#### Inspection requested via web by Michael Stimpson- furnace a/c coil co ok
MEC19-00220 Mec-Aging Inspection8/27/20198/27/20198/27/2019 7:44:25 AM FAIL
needs called in for inspection- if no activity will expire permit permit next aging
MEC19-00266 Mec-Aging Inspection8/27/20198/27/20198/27/2019 7:42:30 AM CANC
needs called in for inspection when ready- WIP
MEC17-03568 Mec-Aging Inspection8/27/20198/27/20198/27/2019 7:41:47 AM CANC
needs called in for inspection- reopened permit