MEC19-03573
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 4:06:33 PM | P | PART |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - only three units are finished at this time units 3,6,7 furnace ac coil ok
|
MEC19-03288
| Pressure Test | 8/26/2019 | 8/27/2019 | 8/27/2019 3:27:26 PM | A | PASS |
|
|
Please call Larry prior to heading out to ensure on pressure. Phone #: ###-#### Inspection requested via web by Andrea Grigsby - 5lb flue pressure test ok - final ok
|
MEC19-01675
| Final | 8/26/2019 | 8/27/2019 | 8/27/2019 2:57:13 PM | P | FAIL |
|
|
Field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - need air balance report onsite - duct blast sticker needs info filled out
|
MEC19-03134
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 2:55:26 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-03788
| Final | 8/26/2019 | 8/27/2019 | 8/27/2019 2:41:34 PM | P | FAIL |
|
|
Call HO Bill ###-#### // Phone #: ###-#### Inspection requested via web by Michael Stimpson - need to see proper UL connectors on mc cables from the outdoor unit to the indoor units - need to see an electricl permit updated to show new ductless split (homeowner has an electrical permit already) - condensate line down stairs needs to be min 3/4" approved material and grade out building.
|
MEC19-02488
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 2:13:19 PM | P | PASS |
|
|
lock box code is 3380 Phone #: ###-#### Inspection requested via web by Lynn Johnston - final ok
|
MEC19-03838
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 1:25:54 PM | P | NH |
|
|
PLEASE CALL JASON THE HOMEOWNER WHEN 30 MINS IN ROUTE. HE HAS TO PICK HIS KIDS UP FROM 315-345P- IF YOU CAN WORK AROUND THAT HE WOULD BE VERY GRATEFUL Phone #: ###-#### Inspection requested via web by Rick Montgomery - no access left notice on front door
|
MEC19-03333
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 1:09:47 PM | P | PASS |
|
|
Call ahead to the home owner = Lester @ ###-#### Phone #: ###-#### Inspection requested via web by Angie Maguire - final ok
|
MEC19-03063
| Final | 8/27/2019 | 8/27/2019 | 8/27/2019 12:46:41 PM | P | PASS |
|
|
this is for a business and they are open 8a-5p, just head out when your ready. I left my office number above, my name is Steve with Diamond Heating and Cooling Phone #: ###-#### Inspection requested via web by Rick Montgomery - A/C coil ok
|
MEC19-02852
| Rough-in | 8/26/2019 | 8/27/2019 | 8/27/2019 11:58:42 AM | P | PART |
|
|
This is a rough-in for Phase 4 of the project. Please call Glen with any questions. Thank you. Phone #: ###-#### Inspection requested via web by Yvonne Bowman - phase 4 partial R/I ok duct seal ok - ok for insulation cover
|
MEC19-03806
| Pressure Test | 8/23/2019 | 8/27/2019 | 8/27/2019 11:35:22 AM | A | PASS |
|
|
Please contact Tom prior to arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - 20lb gas pressure test ok - need to see an electrical permit ( homeowner said he was going to pull a homeowners permit)
|
MEC19-03828
| Final | 8/26/2019 | 8/27/2019 | 8/27/2019 10:32:06 AM | A | CANC |
|
|
Please call general contractor, Joshua Jackson, ###-#### to meet you there. Phone #: ###-#### Inspection requested via web by Mary LaFayette - rescheduled as a R/I and gave it a partial - need to see supply under cabinet ducted out
|
MEC19-03828
| Rough-in | 8/27/2019 | 8/27/2019 | 8/27/2019 10:28:29 AM | A | PART |
|
|
Please call general contractor, Joshua Jackson, ###-#### to meet you there. Phone #: ###-#### Inspection requested via web by Mary LaFayette - supply and return ducting relocate R/I ok - need to see supply under kitcken cabinet ducted out
|
MEC19-03816
| Pressure Test | 8/26/2019 | 8/27/2019 | 8/27/2019 9:45:54 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Michele Atwood - 60lb gas pressure test ok - backfill ok
|
MEC19-00346
| Pressure Test | 8/26/2019 | 8/27/2019 | 8/27/2019 9:27:09 AM | A | PASS |
|
|
Albert Phone #: ###-#### - 60lb gas pressure test ok - tagged meter location
|
MEC19-00216
| Mec-Aging Inspection | 8/27/2019 | 8/27/2019 | 8/27/2019 9:08:28 AM | | DONE |
|
|
Called Contractor about their mechanical aging permit. An electrical permit still needs to be pulled for the mini split and a final inspection scheduled. Permit has not been active since Jan. 2019 and will expire at the next aging inspection if not active.
|
MEC19-00268
| Mec-Aging Inspection | 8/27/2019 | 8/27/2019 | 8/27/2019 9:01:30 AM | | DONE |
|
|
WIP
|
MEC19-02911
| Final | 8/22/2019 | 8/27/2019 | 8/27/2019 8:58:33 AM | A | FAIL |
|
|
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart - need air balance report onsite - water heater b vent needs supported
|