ELE02-02228
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | A | PASS |
|
|
ceiling; Phone #: ###-#### ok 8/28/2002 1:05:34 PM
|
ELE02-02664
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | A | FAIL |
|
|
###-#### need to meet with contractor called bonding for spa p/s all messed up address sub panel grds and neutrals service panel altered calc service size 8/28/2002 12:29:01 PM
|
ELE02-02641
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | A | FAIL |
|
|
###-#### cor. posted 45.00 fee due same corrections PLass posted plus kitchen shall be wired too meet 2002 NEC called 8/28/2002 11:17:42 AM
|
ELE02-02267
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | A | PASS |
|
|
###-#### ok 8/28/2002 12:03:51 PM
|
ELE02-02654
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | A | FAIL |
|
|
###-#### or ###-#### cor. posted called 210.52(B)(C) remove disposal from kit circuit, box fill, free length and shall not use red wire as grd circuit for micro wave 314.43 remove screws from inside of plastic boxes 8/28/2002 12:02:36 PM
|
ELE02-02242
| Electrical Rough-In | 8/27/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | P | PASS |
|
|
ceiling insp john- ###-#### ok 8/28/2002 5:34:28 PM
|
ELE02-02513
| Electrical Rough-In | 8/28/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | P | FAIL |
|
|
wall\\###-#### cor. posted called348.30 strap flex within 12 inches of boxes,352.30 pvc within 3ft of boxes , 358.30 emt within 3ft of boxes, 300.4(A)(1)and (D) nail plates, and 11/4 inches for all flex 8/28/2002 4:27:28 PM
|
ELE02-02674
| Electrical Rough-In | 8/28/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | P | PASS |
|
|
als elec ###-#### r/i ok 8/28/2002 4:59:33 PM
|
ELE02-02215
| Final | 8/28/2002 | 8/28/2002 | 8/28/2002 12:00:00 AM | P | PASS |
|
|
call first ###-#### ok card signed 8/28/2002 6:27:57 PM
|