ELE06-01631
| ELE-Aging Inspection | 8/28/2006 | 8/28/2006 | 9/1/2006 1:37:05 PM | | DONE |
|
|
|
ELE05-02730
| ELE-Aging Inspection | 8/28/2006 | 8/28/2006 | 8/29/2006 7:51:57 AM | | PART |
|
|
wsuc
|
ELE06-03173
| Rough-In Permanent Service | 8/28/2006 | 8/28/2006 | 8/28/2006 3:35:08 PM | P | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt r/i only ok corr for p/s 314.3 needs bond bushings for metal raceways in plastic jbox, 110.26(F)(2) remove a/c lines from below p/s, use plastic conn for GEC at p/s
|
ELE06-00554
| Electrical Rough-In | 8/28/2006 | 8/28/2006 | 8/28/2006 2:59:54 PM | P | FAIL |
|
|
richard ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. met owner's son 300.4 nail plates 11/4", 210.52(B) address SABC, 250.148 splice all equip grds grd together at boxes 14 and 12, 110.2&3 cheetah boxes are not classed for fire, wall, or ceiling need info, 334.80 seperate cables through 1 hole above panel, talked to Tom A structural needs permit and work done too match they added a living rm and kit house now has 2 kitchens looks like they are making a aprtment out of attached garage told them to go back to plan check and resubmit
|
ELE06-03160
| Permanent Service | 8/28/2006 | 8/28/2006 | 8/28/2006 1:46:54 PM | P | CANC |
|
|
As early as possible; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen see added r/i
|
ELE06-03160
| Electrical Rough-In | 8/28/2006 | 8/28/2006 | 8/28/2006 1:46:28 PM | P | PART |
|
|
As early as possible; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen electrode ok for concrete cover only
|
ELE06-01274
| Final | 8/28/2006 | 8/28/2006 | 8/28/2006 1:27:11 PM | P | PASS |
|
|
garage code 4321; Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok
|
ELE06-02020
| Electrical Rough-In | 8/28/2006 | 8/28/2006 | 8/28/2006 12:45:34 PM | P | PASS |
|
|
eric - reinsp; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley high and low voltage ok walls and ceilings
|
ELE06-03134
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 12:44:42 PM | A | PASS |
|
|
Ron Harrold ###-#### ok corrections made
|
ELE06-01404
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 12:15:52 PM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr. fee due 410.8 clearence closet fixtures unit 8971&75
|
ELE06-01401
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 12:11:36 PM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corr fee due reversed polarity mech. rm
|
ELE06-01405
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 12:10:05 PM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok card signed
|
ELE06-02626
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 10:27:07 AM | A | PASS |
|
|
Ron Harrold ###-####
|
ELE06-02571
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 10:26:53 AM | A | PASS |
|
|
Ron Harrold ###-####
|
ELE06-03005
| Final | 8/25/2006 | 8/28/2006 | 8/28/2006 10:26:38 AM | A | PASS |
|
|
Ron Harrold ###-####
|
ELE06-03082
| Temporary Service | 8/24/2006 | 8/28/2006 | 8/28/2006 9:57:02 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/24/2006 at 11:00:56 AM. Contact: ###-####. t/s u/g new ok
|
ELE06-03083
| Temporary Service | 8/24/2006 | 8/28/2006 | 8/28/2006 9:56:20 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/24/2006 at 11:01:31 AM. Contact: ###-####. t/su/g new ok
|
ELE06-03137
| Permanent Service | 8/26/2006 | 8/28/2006 | 8/28/2006 8:35:38 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson p/s o/h new ok
|
ELE06-03185
| Electrical Rough-In | 8/25/2006 | 8/28/2006 | 8/28/2006 8:13:35 AM | A | PART |
|
|
need inspection on U/G for cover. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH u/g inside of building and electrode ok only outside u/g shall be be 18" or under concrete called
|