Inspections for the day of: Tuesday, August 28, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01749 ELE-Aging Inspection8/28/20188/28/20188/31/2018 3:29:23 PM DONE
DOC expired permit
ELE13-01899 ELE-Aging Inspection8/28/20188/28/20188/31/2018 3:26:58 PM DONE
contractor been notified
ELE18-01034 Final8/28/20188/28/20188/28/2018 3:26:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
ELE18-03273 Final8/27/20188/28/20188/28/2018 2:52:46 PMPNR
Late afternoon if possible Phone #: ###-#### Inspection requested via web by Same Electric...windows within 5ft of tub waterline shall be tempered, light within 5ft of tub shall be nonmettalic and GFCI protected, metal gazebo shall be bonded to hot tub, and load calculation on 100A panel is required to approve addition of 40A hot tub breaker on bussing
ELE18-03273 Electrical Rough-In8/28/20188/28/20188/28/2018 2:47:18 PMPPASS
Late afternoon if possible Phone #: ###-#### Inspection requested via web by Same Electric...8/3 romex thru attic for 40A hot tub circuit...GFCI protected disconnect...pvc ran to tub...underground correct depth ok to cover
ELE18-02703 Final8/28/20188/28/20188/28/2018 2:13:46 PMPPEND
Early as possible please -Crew needs to be off site by 10:00 am. Phone #: ###-#### Inspection requested via web by Laurie Hoelscher...contractor rep Drew ###-#### stated job complete...pillar lights being installed by others...others will need to pull permit for work..will final permit once verified permit pulled by others
ELE18-01686 Electrical Rough-In8/27/20188/28/20188/28/2018 1:44:41 PMPPASS
Ceiling cover. Von is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen... northside complete ceiling grid and remaining southside ceiling grid...Lobby is only area left-ceilings undecided
ELE18-03281 Electrical Rough-In8/27/20188/28/20188/28/2018 1:12:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Dustin Kuester...ok to cover walls and ceiling fished in or using existing lighting
ELE18-03000 Electrical Rough-In8/28/20188/28/20188/28/2018 12:55:24 PMPPASS
Pls contact Brad (Foreman) @ ###-#### or Preston (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes...

UL listed equipment...rough-start of solar install...discussed install, feeds thru attic of shed, pipe to house from shed existing, bonding and grounding so far
ELE18-03287 Final8/28/20188/28/20188/28/2018 12:18:44 PMPPASS
Call homeowner when on the way please ###-####

Ground works inspection Phone #: ###-#### Inspection requested via web by Eric Schroeder....finalling permit...is for underground to existing service which ID Power does inspection...changing from overhead to underground...proper depth oked by ID Power not Boise City
ELE18-01571 Electrical Rough-In8/28/20188/28/20188/28/2018 11:29:47 AMPPASS
Requesting inspection of rough-in wiring work in shop prior to final and cover. Phone #: ###-#### Inspection requested via web by Cameron Craven...rough ok to cover...check at final neutrals and grounds seperated at shop panel
ELE18-03085 Final8/27/20188/28/20188/28/2018 11:07:46 AMAPASS
call 30 mins ahead-Clark Phone #: ###-####...finalling out permit...work was done and corrections made by Electrical contractor permit number ELE18-03280
ELE18-03280 Final8/27/20188/28/20188/28/2018 11:02:41 AMAPASS
Please call Mitch 30 minutes prior. Phone #: ###-#### Inspection requested via web by Mitch Whited...contractor to take responsibility for work done without an inspection...inspection was done by contractor and code violations per permit ELE18-03085 were fixed...ok to final permit
ELE18-03287 Final8/28/20188/28/20188/28/2018 10:18:07 AMPCANC
Ground works inspection Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Inspection cancelled from web by: Eric Schroeder
ELE18-03167 Final8/28/20188/28/20188/28/2018 9:38:12 AMPPASS
Chris Phone #: ###-####...UL label and disconnect ok to final
ELE18-03272 Final8/27/20188/28/20188/28/2018 9:20:43 AMANR
Inspection requested via web by Same Electric..

contractor needs to provide access to work done..will reschedule and meet to get access
ELE18-00849 Electrical Rough-In8/27/20188/28/20188/28/2018 9:01:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...remaining East wall...wallcover complete