FIR19-00629
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 5:49:45 PM | P | FAIL |
|
|
Could not get access fire alarm panel, ne inspection/testing performed.
Needs to be done after 5:00pm Phone #: ###-#### Inspection requested via web by Sam Ball
|
FIR19-00628
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 5:49:03 PM | P | PASS |
|
|
Final fire sprinkler inspection for area of work complete.
Has to be done after 5:00pm Phone #: ###-#### Inspection requested via web by Sam Ball
|
FIR18-00844
| INSP-Final Inspection | 8/26/2019 | 8/28/2019 | 8/28/2019 4:10:31 PM | P | PASS |
|
|
Final fire sprinkler inspection complete.
Jon Beazer is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
|
FIR18-00633
| INSP-Sprinkler Rough-in | 8/28/2019 | 8/28/2019 | 8/28/2019 3:47:10 PM | P | PASS |
|
|
Rough to cover inspection for overhead fire sprinkler piping on level 1 complete, approved for cover.
|
FIR18-00633
| INSP-Sprinkler Rough-in/Hydro | 8/27/2019 | 8/28/2019 | 8/28/2019 3:46:22 PM | P | DONE |
|
|
Hydrostatic test for overhead fire sprinkler piping on level 1 witnessed, no pressure loss was observed.
Kenny Caldwell is the contact. He would like this inspection to be a TCO as well as a hydro for the 1st floor. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
|
FIR18-00533
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:37:01 PM | P | PASS |
|
|
Final fire alarm inspection complete.
Phone #: 2088990672 >> Inspection requested via mobile web by Josiah
|
FIR18-00534
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:36:28 PM | P | PASS |
|
|
Final fire alarm inspection complete.
Phone #: 2088990672 >> Inspection requested via mobile web by Josiah
|
FIR19-00196
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:34:50 PM | P | PASS |
|
|
Final inspection for heat trace monitoring complete.
Phone #: 2088990672 >> Inspection requested via mobile web by Josiah
|
FIR19-00195
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:33:37 PM | P | PASS |
|
|
Final inspection for heat trace monitoring complete.
Phone #: 2088990672 >> Inspection requested via mobile web by Josiah
|
FIR18-00812
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:29:15 PM | P | PASS |
|
|
Final inspection for underground supply complete.
Jon Beazer is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
|
FIR18-00601
| INSP-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 1:28:32 PM | P | PASS |
|
|
Final underground supply inspection complete.
Jon Beazer is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
|
FIR18-00830
| INSP-Final Inspection | 8/26/2019 | 8/28/2019 | 8/28/2019 1:19:32 PM | P | FAIL |
|
|
Level 1 flow switch did not operate correctly during waterflow, flow switch would not go into alarm automatically.
Jon Beazer is the contact. Thank you for your hard work! Phone #: ###-#### Inspection requested via web by Stan Beus
|
BLD19-00905
| FIRE-Final Inspection | 8/28/2019 | 8/28/2019 | 8/28/2019 1:17:44 PM | P | CANC |
|
|
Fire alarm permit for fire alarm modifications in the same area has not been finaled, FIR17-00186. Scope of work needs to be completed for the FIR permit before life fire safety can be completed for the recent modifications. Informed point of contact about fire alarm issue as well. JCI, formally SimplexGrinnell has been notified about the issue as well, this request is cancelled.
nATE Phone #: ###-####
|
BLD19-02852
| FIRE-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 10:30:07 AM | A | PASS |
|
|
No fire sprinkler modifications, no fire alarm modifications, fire extinguisher is placed with a current inspection tag. Final life fire safety inspection for area of work complete.
Justin Phone #: ###-####
|
BLD19-00286
| FIRE-Final Inspection | 8/27/2019 | 8/28/2019 | 8/28/2019 10:16:56 AM | A | FAIL |
|
|
Provide code compliant door hardware for breakroom door. Provide a fire extinguisher with a current ispection tag, current tag is from 1986. Thumbturn deadbolt on main entry needs to be changed to a double-key deadbolt and provide signage at main door reading "Door to remain unlocked while building is occupied".
The building will be open at 9. Ask for Becca at the front desk. She has the approved plans. Thank you. Jay Phone #: ###-#### Inspection requested via web by Jay Bedsole
|
FIR19-00573
| INSP-Sprinkler Rough-in | 8/27/2019 | 8/28/2019 | 8/28/2019 9:44:19 AM | A | PART |
|
|
Rough to cover inspection for overhead fir esprinkler piping above hardlids complete, approved for cover.
Kerry Phone #: ###-####
|