Inspections for the day of: Monday, August 29, 2016.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01478 ELE-Aging Inspection8/29/20168/29/20168/29/2016 2:47:19 PM DONE
too busy
ELE16-02748 Rough-In Permanent Service8/29/20168/29/20168/29/2016 2:46:44 PMPCANC
Door code CAM, if you have any questions, please call the lead on the job, Luke at ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan see ri
ELE16-02748 Electrical Rough-In8/29/20168/29/20168/29/2016 2:46:27 PMPPASS
Door code CAM, if you have any questions, please call the lead on the job, Luke at ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan ri ok bath, kitchen, new bedroom at rear
ELE16-02004 Final8/29/20168/29/20168/29/2016 2:44:39 PMPPASS
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk ok final
ELE16-02090 Final8/29/20168/29/20168/29/2016 2:43:50 PMPPASS
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk ok final
ELE16-02668 Final8/29/20168/29/20168/29/2016 2:43:08 PMPPASS
well house ready to final Phone #: ###-#### Inspection requested via web by Bob Glenn ok final
ELE16-02288 Final8/29/20168/29/20168/29/2016 1:26:26 PMPPASS
call prior to arrival for access instructions Phone #: ###-#### Inspection requested via web by Patrick Paz ok final
ELE16-00082 Final8/27/20168/29/20168/29/2016 12:32:29 PMAPART
units 121 123 125 127 220 Phone #: ###-#### Inspection requested via web by Tracy Robertson ok as requested
ELE16-00080 Final8/27/20168/29/20168/29/2016 11:41:18 AMAPART
units 105 107 109 110 113 115 210 Phone #: ###-#### Inspection requested via web by Tracy Robertson ok as requested
ELE16-02775 Electrical Rough-In8/28/20168/29/20168/29/2016 9:44:54 AMAFAIL
Phone #: ###-#### Inspection requested via web by shane miller called, left correction notice, NEC 314.23 shall not use screws inside box not listed for the purpose, 300.4(A) shall install steel plate if edge of bored hole is less than 1 1/4" fron edge of framing member, 334.30 shall securely fasten nm cabe within 12" of termination, 210.52(E) shall install receptacle at front and rear of dwelling
ELE16-02748 Rough-In Permanent Service8/26/20168/29/20168/29/2016 8:49:45 AMACANC
Door code is CAM, our guys should be there if you have any questions. Luke is the J-man on the job. Thank you! Phone #: ###-#### Inspection requested via web by Clay Morgan see p/s
ELE16-02748 Permanent Service8/29/20168/29/20168/29/2016 8:41:06 AMAPASS
Door code is CAM, our guys should be there if you have any questions. Luke is the J-man on the job. Thank you! Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok
ELE16-02036 Final8/29/20168/29/20168/29/2016 8:38:24 AMAPASS
access 1234 Phone #: ###-#### Inspection requested via web by David Nelson ok final