Inspections for the day of: Monday, August 29, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-03908 Rough-in8/29/20168/29/20168/29/2016 4:34:40 PMPPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
MEC16-02800 Rough-in8/25/20168/29/20168/29/2016 3:46:15 PMPPASS
PLease call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
MEC16-03923 Final8/29/20168/29/20168/29/2016 3:41:57 PMPPART
Phone #: ###-#### Inspection requested via web by Marisa Hone
attic ac and furnace ok
MEC16-03888 Final8/25/20168/29/20168/29/2016 2:52:54 PMPPASS
doing the install today, later afternoon would be wonderful.
Thanks and have a great day! Inspection requested via web by Rick Montgomery
MEC16-02800 Pressure Test8/25/20168/29/20168/29/2016 2:26:16 PMPFAIL
PLease call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
gauge didnt zero out
MEC16-03908 Pressure Test8/29/20168/29/20168/29/2016 2:02:13 PMPPASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN-
20lb gas, 5lb flue
MEC16-02146 Final8/26/20168/29/20168/29/2016 1:19:22 PMPPASS
final for us

thanks! Phone #: ###-#### Inspection requested via web by Brian Preece
MEC16-03338 Final8/25/20168/29/20168/29/2016 12:51:04 PMAFAIL
We will be out @ 10 AM - if you are available about 10:30 or later, we will have the CO detectors installed. Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
talked with homeowener, said they didnt leave a c.o. alarm
MEC15-04633 Rough-in8/26/20168/29/20168/29/2016 10:55:36 AMAPART
Rough in on grease duct, please call Brad. Thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum.
fix pin holes
MEC16-03000 Rough-in8/29/20168/29/20168/29/2016 9:47:28 AMAPASS
R/I inspection request 3rd and 4th floor cover inspection. Please call job lead Daryl Hulse ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery
3rd and 4th floor exhaust in walls ok to cover
MEC16-03924 Final8/29/20168/29/20168/29/2016 9:36:03 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Marisa Hone Inspection cancelled from web by: Marisa Hone
MEC16-03596 Rough-in8/26/20168/29/20168/29/2016 9:18:56 AMAFAIL
Oleg Phone #: ###-####-
add pipe to your taps so 26 gage pipe extends through the fire rated cieling. pipe also needs to be insulated
MEC16-00547 Mec-Aging Inspection8/29/20168/29/20168/29/2016 8:44:30 AM CANC
MEC16-00563 Mec-Aging Inspection8/29/20168/29/20168/29/2016 8:43:56 AM PEND
MEC16-00563 DOC - Permit Finaled8/29/20168/29/20168/29/2016 8:43:44 AMPPASS