MIS18-00328
| MEC-Conference | 8/28/2018 | 8/29/2018 | 8/30/2018 10:29:08 AM | A | DONE |
|
|
work done w/o permits there is working being done on a new master suite with permit MEC18-04154- there was also some work done a pool equipment room/ bathroom and the only thing that needs to be taken care of is the b vent for the pool heater needs 1" clearances to combustibles- there is also a water heater vent that needs 1" clearances to combustibles
|
MEC18-04214
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 4:36:05 PM | P | PASS |
|
|
INSTALLER ARCHIE ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
|
MEC17-04207
| Final | 8/29/2018 | 8/29/2018 | 8/29/2018 3:58:56 PM | P | PASS |
|
|
We were unable to reach the customer to schedule an inspection. Jack requested that I call this inspection in so he could leave a notice on their door, because their permit is about to expire. Phone #: ###-#### Inspection requested via web by Krista Boss - ductless split system multi port final ok
|
MEC18-03032
| Final | 8/29/2018 | 8/29/2018 | 8/29/2018 3:46:45 PM | P | FAIL |
|
|
please call office 30 mins prior to arrival . We will make sure ladder is there for you to access attic Phone #: ###-#### Inspection requested via web by Rick Montgomery- this is the furnace above the visitor center - Common b vent needs 1" clearances- need a drip leg in gas line- wet switch needs to be sealed to pan or replace with a hockey puck style wet switch- need to reinstall refrigerant clamps at A/C
|
MEC18-03115
| Final | 8/29/2018 | 8/29/2018 | 8/29/2018 3:46:02 PM | P | FAIL |
|
|
please call office 30 mins prior to arrival . We will make sure ladder is there for you to access attic Phone #: ###-#### Inspection requested via web by Rick Montgomery- this is the furnace above the hallway - need clearances on common b vent- lineset insulation in attic needs taped- need to replace wet switch with a hockey puck wet switch. the wet switch that is installed is not sealed to drain pan properly- A/C needs refrigerant clamps reinstalled-
|
MEC18-04208
| DOC - Permit Finaled | 8/29/2018 | 8/29/2018 | 8/29/2018 3:06:01 PM | P | PASS |
|
|
final ok
|
MEC18-04208
| Pressure Test | 8/29/2018 | 8/29/2018 | 8/29/2018 3:05:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ron Arnold- 20 lb gas pressure test to range ok
|
MEC18-04220
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 2:54:43 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aaron - furnace only ok co ok- need to see a permit pulled for the water before final for furnace
|
MEC18-04110
| Final | 8/22/2018 | 8/29/2018 | 8/29/2018 2:35:18 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
|
MEC18-02583
| Pressure Test | 8/29/2018 | 8/29/2018 | 8/29/2018 2:18:08 PM | P | PASS |
|
|
Please call customer when on way: Toni ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 20 lb gas pressure test ok- ok for cover
|
MEC18-04158
| Rough-in | 8/28/2018 | 8/29/2018 | 8/29/2018 1:46:44 PM | P | PART |
|
|
Rough in Inspection for Duct. Aaron Roberts is the site contact at ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical- duct seal ok- ok for insulation-need to see one more strap added to piping- this building is the far south space of building A
|
MEC18-03050
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 1:44:01 PM | P | PASS |
|
|
Final inspection of HVAC DUct and Equipment. Aaron Roberts is the site contact: ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical- final ok card signed
|
MEC18-03473
| Final | 8/23/2018 | 8/29/2018 | 8/29/2018 1:11:15 PM | P | PASS |
|
|
Please call homeowner 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs - furnace ac coil co ok
|
MEC18-04087
| Final | 8/26/2018 | 8/29/2018 | 8/29/2018 11:39:31 AM | A | PASS |
|
|
Property Rental people Phone #: ###-#### Inspection requested via web by Baldomero Guzman- A/C coil co ok
|
MEC18-03354
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 11:32:24 AM | A | PART |
|
|
PLEASE CALL HOMEOWNER DON WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- A/C and coil ok- need to see gasline tied into furnace- gas line penetration needs sealed- need to install co detectors
|
MEC18-03354
| Pressure Test | 8/28/2018 | 8/29/2018 | 8/29/2018 11:30:47 AM | A | PASS |
|
|
PLEASE CALL HOMEOWNER DON WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- 20lb gas pressure test ok
|
MEC18-02692
| Final | 8/29/2018 | 8/29/2018 | 8/29/2018 11:02:39 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace final ok
|
MEC18-04229
| Rough-in | 8/28/2018 | 8/29/2018 | 8/29/2018 11:02:03 AM | A | FAIL |
|
|
Kaz Lawler is point of contact Phone #: ###-#### Inspection requested via web by Sheldon Lebow- horizantal flue pipe running in the floor above needs 3 " clearances to combustibles- need to see framing finished by homeowner at fireplace
|
MEC18-02472
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 10:09:11 AM | A | PASS |
|
|
Duct blast Witness at 9 am Logan will let you in, thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- duct blast ok- final ok
|
MEC18-03786
| Final | 8/26/2018 | 8/29/2018 | 8/29/2018 9:49:03 AM | A | FAIL |
|
|
Lee Walton owner Phone #: ###-#### Inspection requested via web by Baldomero Guzman- no access to home- schedule with home owner
|
MEC18-03380
| Final | 8/23/2018 | 8/29/2018 | 8/29/2018 9:34:55 AM | A | PASS |
|
|
Please call Laurie in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- A/C coil co ok
|
MEC18-04145
| Rough-in | 8/28/2018 | 8/29/2018 | 8/29/2018 9:26:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplaxce R/I ok
|
MEC17-01544
| Mec-Aging Inspection | 8/29/2018 | 8/29/2018 | 8/29/2018 9:03:31 AM | | DONE |
|
|
talked with contractor about job and they are still working on this job. they are waiting on some information from owner which should be happening this week some time- if project doesnt move foward contractor is thinking of pulling out of job
|
MEC17-05415
| Mec-Aging Inspection | 8/29/2018 | 8/29/2018 | 8/29/2018 8:58:23 AM | | DONE |
|
|
called Alpine FIreplaces and left a message with Mike
|
MEC17-04207
| Mec-Aging Inspection | 8/29/2018 | 8/29/2018 | 8/29/2018 8:56:56 AM | | DONE |
|
|
talked with A-1 about scheduling an inspection with home owners
|
MEC18-02222
| Final | 8/28/2018 | 8/29/2018 | 8/29/2018 8:38:57 AM | A | FAIL |
|
|
if no body there call for access // Jonny Phone #: ###-#### - furnace in basement needs a wet switchh installed in the secoundary- condensate drain for heating side of furnace is not ran- need to finish duct seal- upstairs furnace needs lineset insulation fixed- need drip leg in gas line- need to finish duct seal- kitcken exhaust ok
|
MEC18-03837
| Final | 8/28/2018 | 8/29/2018 | 8/28/2018 1:30:09 PM | A | CANC |
|
|
Please inspect late AM. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|