Inspections for the day of: Wednesday, August 29, 2018.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS18-00328 MEC-Conference8/28/20188/29/20188/30/2018 10:29:08 AMADONE
work done w/o permits
there is working being done on a new master suite with permit MEC18-04154- there was also some work done a pool equipment room/ bathroom and the only thing that needs to be taken care of is the b vent for the pool heater needs 1" clearances to combustibles- there is also a water heater vent that needs 1" clearances to combustibles
MEC18-04214 Final8/28/20188/29/20188/29/2018 4:36:05 PMPPASS
INSTALLER ARCHIE ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
MEC17-04207 Final8/29/20188/29/20188/29/2018 3:58:56 PMPPASS
We were unable to reach the customer to schedule an inspection. Jack requested that I call this inspection in so he could leave a notice on their door, because their permit is about to expire. Phone #: ###-#### Inspection requested via web by Krista Boss
- ductless split system multi port final ok
MEC18-03032 Final8/29/20188/29/20188/29/2018 3:46:45 PMPFAIL
please call office 30 mins prior to arrival . We will make sure ladder is there for you to access attic Phone #: ###-#### Inspection requested via web by Rick Montgomery- this is the furnace above the visitor center - Common b vent needs 1" clearances- need a drip leg in gas line- wet switch needs to be sealed to pan or replace with a hockey puck style wet switch- need to reinstall refrigerant clamps at A/C
MEC18-03115 Final8/29/20188/29/20188/29/2018 3:46:02 PMPFAIL
please call office 30 mins prior to arrival . We will make sure ladder is there for you to access attic Phone #: ###-#### Inspection requested via web by Rick Montgomery- this is the furnace above the hallway - need clearances on common b vent- lineset insulation in attic needs taped- need to replace wet switch with a hockey puck wet switch. the wet switch that is installed is not sealed to drain pan properly- A/C needs refrigerant clamps reinstalled-
MEC18-04208 DOC - Permit Finaled8/29/20188/29/20188/29/2018 3:06:01 PMPPASS
final ok
MEC18-04208 Pressure Test8/29/20188/29/20188/29/2018 3:05:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Ron Arnold- 20 lb gas pressure test to range ok
MEC18-04220 Final8/28/20188/29/20188/29/2018 2:54:43 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aaron - furnace only ok co ok- need to see a permit pulled for the water before final for furnace
MEC18-04110 Final8/22/20188/29/20188/29/2018 2:35:18 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
MEC18-02583 Pressure Test8/29/20188/29/20188/29/2018 2:18:08 PMPPASS
Please call customer when on way: Toni ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 20 lb gas pressure test ok- ok for cover
MEC18-04158 Rough-in8/28/20188/29/20188/29/2018 1:46:44 PMPPART
Rough in Inspection for Duct. Aaron Roberts is the site contact at ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical- duct seal ok- ok for insulation-need to see one more strap added to piping- this building is the far south space of building A
MEC18-03050 Final8/28/20188/29/20188/29/2018 1:44:01 PMPPASS
Final inspection of HVAC DUct and Equipment. Aaron Roberts is the site contact: ###-#### Phone #: ###-#### Inspection requested via web by RM Mechanical- final ok card signed
MEC18-03473 Final8/23/20188/29/20188/29/2018 1:11:15 PMPPASS
Please call homeowner 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs
- furnace ac coil co ok
MEC18-04087 Final8/26/20188/29/20188/29/2018 11:39:31 AMAPASS
Property Rental people Phone #: ###-#### Inspection requested via web by Baldomero Guzman- A/C coil co ok
MEC18-03354 Final8/28/20188/29/20188/29/2018 11:32:24 AMAPART
PLEASE CALL HOMEOWNER DON WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- A/C and coil ok- need to see gasline tied into furnace- gas line penetration needs sealed- need to install co detectors
MEC18-03354 Pressure Test8/28/20188/29/20188/29/2018 11:30:47 AMAPASS
PLEASE CALL HOMEOWNER DON WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- 20lb gas pressure test ok
MEC18-02692 Final8/29/20188/29/20188/29/2018 11:02:39 AMPPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace final ok
MEC18-04229 Rough-in8/28/20188/29/20188/29/2018 11:02:03 AMAFAIL
Kaz Lawler is point of contact Phone #: ###-#### Inspection requested via web by Sheldon Lebow- horizantal flue pipe running in the floor above needs 3 " clearances to combustibles- need to see framing finished by homeowner at fireplace
MEC18-02472 Final8/28/20188/29/20188/29/2018 10:09:11 AMAPASS
Duct blast Witness at 9 am Logan will let you in, thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- duct blast ok- final ok
MEC18-03786 Final8/26/20188/29/20188/29/2018 9:49:03 AMAFAIL
Lee Walton owner Phone #: ###-#### Inspection requested via web by Baldomero Guzman- no access to home- schedule with home owner
MEC18-03380 Final8/23/20188/29/20188/29/2018 9:34:55 AMAPASS
Please call Laurie in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- A/C coil co ok
MEC18-04145 Rough-in8/28/20188/29/20188/29/2018 9:26:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplaxce R/I ok
MEC17-01544 Mec-Aging Inspection8/29/20188/29/20188/29/2018 9:03:31 AM DONE
talked with contractor about job and they are still working on this job. they are waiting on some information from owner which should be happening this week some time- if project doesnt move foward contractor is thinking of pulling out of job
MEC17-05415 Mec-Aging Inspection8/29/20188/29/20188/29/2018 8:58:23 AM DONE
called Alpine FIreplaces and left a message with Mike
MEC17-04207 Mec-Aging Inspection8/29/20188/29/20188/29/2018 8:56:56 AM DONE
talked with A-1 about scheduling an inspection with home owners
MEC18-02222 Final8/28/20188/29/20188/29/2018 8:38:57 AMAFAIL
if no body there call for access // Jonny Phone #: ###-####
- furnace in basement needs a wet switchh installed in the secoundary- condensate drain for heating side of furnace is not ran- need to finish duct seal- upstairs furnace needs lineset insulation fixed- need drip leg in gas line- need to finish duct seal- kitcken exhaust ok
MEC18-03837 Final8/28/20188/29/20188/28/2018 1:30:09 PMACANC
Please inspect late AM. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette