ELE06-02298
| Permanent Service | 8/3/2006 | 8/3/2006 | 8/3/2006 4:26:34 PM | P | FAIL |
|
|
###-#### - marv 250.52(A)(1)or104(A)(1) grd or bond water sized too T250.66, #2 cu 250.90,92 use bond bushing not bonding locknut, where concentrics are encountered, 250.64(E) use listed or plastic fitting for GEC not 3/8 romex conn., 314.28 j box above service disconnects shall be of large enough size for straight pulls, 312.5(C) exception pvc tob of jbox shall meet rquirements of code noted terminate service wirs to far right panel to main breaker not main lugs use backfed device cow
|
ELE06-00073
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 3:00:20 PM | P | PASS |
|
|
virgil ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok no card
|
ELE06-02767
| Electrical Rough-In | 8/3/2006 | 8/3/2006 | 8/3/2006 2:23:05 PM | P | PART |
|
|
Cover for panel wall; Phone #: ###-#### Internet Inspection Request from: Joe Thomas ok
|
ELE04-01830
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 1:27:12 PM | P | NR |
|
|
please call prior to inspection so it can be opened ###-#### Mike see added r/i
|
ELE04-01830
| Electrical Rough-In | 8/3/2006 | 8/3/2006 | 8/3/2006 1:26:48 PM | P | PART |
|
|
please call prior to inspection so it can be opened ###-#### Mike ok corr. made, bath rm ok, island in kit needs too meet requirements of 210.52 (C)(1) 2ft 4ft rule gave cover contractor will corr. I will check it at time of final
|
ELE06-02827
| Permanent Service | 8/2/2006 | 8/3/2006 | 8/3/2006 12:12:58 PM | P | PASS |
|
|
SCOTT; Phone #: ###-#### Internet Inspection Request from: Sean DeLacyh p/s o/h rec. ok
|
ELE06-02827
| Final | 8/3/2006 | 8/3/2006 | 8/3/2006 12:12:12 PM | A | PASS |
|
|
SCOTT; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok
|
ELE06-02196
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 9:44:03 AM | A | PASS |
|
|
pat; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|
ELE06-02853
| Electrical Rough-In | 8/2/2006 | 8/3/2006 | 8/3/2006 9:09:39 AM | A | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles walls and ceilings
|
ELE06-02860
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 8:30:04 AM | A | PASS |
|
|
This is Unit "H". We wired a new 120 volt receptacle for gas range to plug into and fed it from the existing counter top receptacle to the right of the range.(6070781w)Tech/Dan/###-####. Thanks!!!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok
|
ELE06-01128
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 7:54:58 AM | A | CANC |
|
|
code ###-####; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE06-01127
| Final | 8/2/2006 | 8/3/2006 | 8/3/2006 7:54:29 AM | A | CANC |
|
|
code ###-####; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE06-01129
| Final | 8/3/2006 | 8/3/2006 | 8/3/2006 7:53:57 AM | A | CANC |
|
|
code ###-####; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE06-00896
| Final | 8/3/2006 | 8/3/2006 | 8/3/2006 7:52:58 AM | A | CANC |
|
|
code ###-####; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|
ELE06-00895
| Final | 8/3/2006 | 8/3/2006 | 8/3/2006 7:52:42 AM | A | CANC |
|
|
code ###-####; Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|