PLM15-02543
| Plumbing Rough-in | 7/31/2015 | 8/3/2015 | 8/3/2015 2:37:56 PM | A | FAIL |
|
|
Any question call Brandon Phone #: ###-#### Inspection requested via web by Stacia Haumann multiple code violations.........ds
|
PLM15-02578
| Final | 8/2/2015 | 8/3/2015 | 8/3/2015 2:35:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marion Moody
|
PLM14-03125
| PLM-Aging Inspection | 8/3/2015 | 8/3/2015 | 8/3/2015 12:17:38 PM | | PEND |
|
|
|
PLM13-03212
| PLM-Aging Inspection | 8/3/2015 | 8/3/2015 | 8/3/2015 11:50:29 AM | | PEND |
|
|
|
PLM15-02579
| Plumbing Rough-in | 7/31/2015 | 8/3/2015 | 8/3/2015 10:26:36 AM | A | FAIL |
|
|
Martha ###-#### change out san tees in horizontal drain , combos for k/s and lav, pex pipe on water heater within 18 inches and cannot use pex on t&p, support drain every 4 ft. and hook up tub drain and nail plate..........ds
|
PLM15-02525
| Water Heater Final | 7/29/2015 | 8/3/2015 | 8/3/2015 9:51:37 AM | A | PASS |
|
|
Water heater install - Homeowner requests am appointment. Please call when en route ###-####. Thank you Phone #: ###-#### Inspection requested via web by TERRY SIDWELL
|
PLM15-02544
| Final | 7/31/2015 | 8/3/2015 | 8/3/2015 9:33:44 AM | A | PASS |
|
|
Brian ###-####
|