Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02478 Electrical Rough-In8/2/20188/3/20188/3/2018 3:23:47 PMPNR
call when on way // ###-#### Anastasia Beiting
Will recall when nail plates installed, minimum receptacles installed, and securing of NM cables prior to entering boxes.
ELE18-02478 Conference8/3/20188/3/20188/3/2018 3:22:33 PMPDONE
call when on way // ###-#### Anastasia Beiting
Discussed requirements for moving service to outside carport wall and adding subpanel surface of wall where service used to be. Also minimum receptacles required for wall space of rooms and kitchen counter areas. GFCI requirements for bathrooms.
ELE18-02911 Final8/1/20188/3/20188/3/2018 2:29:44 PMPNH
Homeowner will be home all afternoon on Friday 8/3/2018 for final. Thank You Phone #: ###-#### Inspection requested via web by Kelly Felin
No answer at door. Please reschedule.
ELE18-02777 Electrical Rough-In8/3/20188/3/20188/3/2018 1:56:53 PMPPASS
Please call before inspection as I will be in and out. Porte Corche rough in Phone #: ###-#### Inspection requested via web by Ryan Wake
Ceiling noted rough in ok cover
ELE18-02952 Electrical Rough-In8/3/20188/3/20188/3/2018 1:56:01 PMPPASS
Phone #: ###-#### Inspection requested via web by steve ragan
Wall rough in ok cover
ELE18-01854 Electrical Rough-In8/2/20188/3/20188/3/2018 1:16:22 PMPPASS
Ceiling cover Phone #: ###-#### Inspection requested via web by Tom Jenkins
Grid rough in ok cover
ELE18-02773 Electrical Rough-In8/2/20188/3/20188/3/2018 12:03:53 PMAPASS
I will call and Schedule a time to meet you onsite. Phone #: ###-#### Inspection requested via web by Jesse Simpson
Listing confirmed on equipment
ELE18-01153 Final8/2/20188/3/20188/3/2018 12:03:10 PMAFAIL
Access code 1972 Inspection requested via web by jamie berg
110.3- Only 1 receptacle works in master bedroom. Light, smokes, and rest of receptacles not working.
314.25- All boxes shall have covers. Family ceiling, misc switch locations.
406.4(D)- Receptacle replacements, Grounding type receptacles on ungrounded circuits shall have GFCI protection or be changed to ungrounded receptacles.
410.16- Recessed can in master closet shall have totally enclosed lamp
ELE18-02780 Electrical Rough-In8/2/20188/3/20188/3/2018 11:03:24 AMANR
###-#### New framed wall is directly over an outlet. I didnt know if outlet is deleted or if its going to be used. Previous correction was to allow panel to have working clearance.
Work clearance 32w x 32 d, with stud covering receptacle in existing wall. Contractor unable to check out until monday 8-6-18 then will request inspection when ready.
ELE18-02064 Electrical Rough-In8/2/20188/3/20188/3/2018 8:27:22 AMAPASS
Please call prior to arrival for access. ###-#### Phone #: ###-#### Inspection requested via web by Kevin Perez
Kitchen and up master bathroom. Rough in ok cover.