MEC18-02825
| Rough-in | 8/3/2018 | 8/3/2018 | 8/3/2018 4:28:24 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC18-03482
| Pressure Test | 8/3/2018 | 8/3/2018 | 8/3/2018 4:28:09 PM | P | PASS |
|
|
Field super; Daryl Thomas ###-#### Phone #: ###-#### Inspection requested via web by Lisa Whitney - 20lb gas
|
MEC18-03482
| Rough-in | 8/3/2018 | 8/3/2018 | 8/3/2018 4:27:54 PM | P | PASS |
|
|
Field super; Daryl Thomas ###-#### Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC18-02885
| Final | 8/3/2018 | 8/3/2018 | 8/3/2018 3:10:33 PM | P | PASS |
|
|
Final Inspection for Business Interiors. Please call Rob Campbell with any questions ###-#### Phone #: ###-#### Inspection requested via web by Bailey Esposito
|
MEC18-01435
| Final | 8/3/2018 | 8/3/2018 | 8/3/2018 2:52:22 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige - Kitchen equipment has not been installed and connected to the gas piping on the 1st floor
|
MEC18-02578
| Final | 8/2/2018 | 8/3/2018 | 8/3/2018 11:08:39 AM | A | FAIL |
|
|
Please contact Jasper to meet you on site. Please give us 20 minutes notice. Phone #: ###-#### Inspection requested via web by Ted Dumont - Breaker for A/C is oversized, need to seal where lineset penetrates the exterior of te house, Need to extend the pad under the condensing unit out to the edge of the condensing unit
|
MEC18-03458
| Rough-in | 8/2/2018 | 8/3/2018 | 8/3/2018 10:38:48 AM | A | PASS |
|
|
Framing changes were made and had to reinstall fireplace Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC17-03739
| Final | 8/2/2018 | 8/3/2018 | 8/3/2018 10:19:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Petsche
|
MEC18-03806
| Rough-in | 8/2/2018 | 8/3/2018 | 8/3/2018 10:06:37 AM | A | FAIL |
|
|
Please call 30-60 minutes in advance if possible. Phone #: ###-#### Inspection requested via web by Brent Walker - Need to screw and seal exhaust duct joints. Need to install range vent, and dryer duct. Will need combustion air for utility room downstairs.
|
PLM18-03260
| Water Heater Final | 7/31/2018 | 8/3/2018 | 8/3/2018 9:08:19 AM | A | FAIL |
|
|
Carolyn is the property manager and she is hoping you can be there prior to 11am. She has carpet cleaners coming at 11am to clean the carpets in basement. This is also where the water heater is located. If you can call her it would surely be appreciated. Also informed her of needing a CO sensor above the water heater. She said she will get one. Phone #: ###-#### Inspection requested via web by Robert Gomez - Need 1" clearance to combustable material from water heater B-vent.
|
PLM18-03269
| Water Heater Final | 8/2/2018 | 8/3/2018 | 8/3/2018 8:32:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Vaughn Carlson
|
MEC18-03736
| Rough-in | 8/2/2018 | 8/3/2018 | 8/3/2018 8:01:32 AM | A | PASS |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
|
MEC18-03736
| Pressure Test | 8/2/2018 | 8/3/2018 | 8/3/2018 8:01:21 AM | A | FAIL |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - Not holding pressure
|