Inspections for the day of: Tuesday, August 30, 2005.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01561 Final8/23/20058/30/20058/30/2005 4:12:09 PMPNH
Scheduled by a contractor via Hello! on 8/23/2005 at 3:19:46 PM. Contact: ###-####. what elevator ?
ELE05-03025 Permanent Service8/30/20058/30/20058/30/2005 4:09:45 PMPPASS
scott; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s o/h rec. ok
ELE05-03161 Final8/30/20058/30/20058/30/2005 3:25:13 PMPPASS
###-#### pat ok
ELE05-03001 Permanent Service8/29/20058/30/20058/30/2005 2:16:20 PMPPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore p/s u/g new ok
ELE05-02979 Final8/30/20058/30/20058/30/2005 2:15:20 PMPFAIL
shane; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. posted called 210.8 needs gfci for recepts in shop, 210.70 needs outside light, 250.24 terminate GEC to neutral bus,and install bond screw, 300.4(D) shall provide 11/4" for MC cable
ELE05-02277 Final8/30/20058/30/20058/30/2005 1:22:10 PMPFAIL
olga; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa all violations not corrected still needs gfci all outside recepts called cor. posted
ELE05-01614 Final8/30/20058/30/20058/30/2005 12:31:03 PMPPASS
allen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE05-02995 Final8/30/20058/30/20058/30/2005 11:43:03 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Jim Williams contractor called and canceled
ELE05-02003 Electrical Rough-In8/30/20058/30/20058/30/2005 10:38:15 AMPPART
Scheduled by a contractor via Hello! on 8/30/2005 at 8:49:15 AM. Contact: ###-####. u/g anop
ELE05-02742 Temporary Service8/29/20058/30/20058/30/2005 10:37:48 AMAPASS
Scheduled by a contractor via Hello! on 8/29/2005 at 9:36:25 AM. Contact: ###-####. t/s u/g new ok
ELE05-03153 Electrical Rough-In8/29/20058/30/20058/30/2005 9:52:27 AMAPART
john ###-#### cor. posted needs to uncover u/g from house to garage, covered before inspection, garage ok called
ELE05-02465 Electrical Rough-In8/29/20058/30/20058/30/2005 9:19:08 AMAPART
Scheduled by a contractor via Hello! on 8/29/2005 at 9:44:20 AM. Contact: ###-####. walls rest rm hard ceilings, and outside soffits
ELE05-02765 Final8/29/20058/30/20058/30/2005 8:35:51 AMAPASS
calvin ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok
ELE05-03116 Permanent Service8/29/20058/30/20058/30/2005 8:02:27 AMAPASS
bill; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa p/s u/g rec. for meter ok
ELE05-03116 Final8/30/20058/30/20058/30/2005 12:00:00 AMAPASS
bill; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
ELE05-03001 Final8/30/20058/30/20058/30/2005 12:00:00 AMPPASS
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok
ELE05-03105 Rough-In Permanent Service8/29/20058/30/20058/29/2005 2:15:12 PMACANC
Call Dave if there are any problems; Phone #: ###-#### Internet Inspection Request from: William Zerfas Inspection cancelled from web by: William Zerfas
ELE05-01298 Final8/29/20058/30/20058/29/2005 12:37:01 PMACANC
lewis; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa Inspection cancelled from web by: Barry Kendall