Inspections for the day of: Friday, August 31, 2001.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorStan Johnson
TitlePLM-INSPECTOR
Phone #340-1257
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM01-02994 Water and/or Sewer8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
swr & water- rob- ###-####
PLM00-04408 Final8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/30/2001 at 12:26:50. Contact: ###-####.
PLM01-02915 Water and/or Sewer8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/30/2001 at 14:31:20. Contact: ###-####.
PLM01-01602 Final8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/30/2001 at 14:33:56. Contact: ###-####.
PLM01-02874 Plumbing Rough-in8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/30/2001 at 15:32:11. Contact: .
PLM01-02998 Plumbing Rough-in8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
DAVID ###-####
PLM01-02146 Final8/30/20018/31/20018/31/2001 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 08/30/2001 at 15:48:14. Contact: ###-####. pass code to garage is 1537
PLM01-03000 Groundwork8/30/20018/31/20018/31/2001 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/30/2001 at 16:25:36. Contact: ###-####.wrap piping through concrete isolate pex main waterline from rebar stakes 8/31/2001 12:36:27 PM
PLM01-01893 Final8/30/20018/31/20018/31/2001 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 08/30/2001 at 21:45:29. Contact: ###-####.waterheater can't be installed in alclove unless clerances are expanded to 6" on sides and 6" in back as per manuf. inst. 8/31/2001 10:13:56 AM
PLM01-02783 Plumbing Rough-in8/31/20018/31/20018/31/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/31/2001 at 07:58:27. Contact: ###-####.
PLM01-02899 Water and/or Sewer8/31/20018/31/20018/31/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/31/2001 at 08:18:18. Contact: ###-####.
PLM01-02898 Water and/or Sewer8/31/20018/31/20018/31/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/31/2001 at 08:19:19. Contact: ###-####.
PLM00-03633 Water and/or Sewer8/31/20018/31/20018/31/2001 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 08/31/2001 at 08:29:43. Contact: ###-####.backflow pvc cannot be used above ground 8/31/2001 12:16:59 PM
PLM00-03633 Water and/or Sewer8/31/20018/31/20018/31/2001 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 08/31/2001 at 08:29:43. Contact: ###-####.backflow pvc cannot be used above ground 8/31/2001 12:16:59 PM
PLM01-02634 Final8/31/20018/31/20018/31/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/31/2001 at 08:36:28. Contact: ###-####.
PLM01-02634 Final8/31/20018/31/20018/31/2001 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/31/2001 at 08:36:28. Contact: ###-####.
PLM01-03000 Water and/or Sewer8/31/20018/31/20018/31/2001 12:00:00 AMPPART
Added by Inspector: 352 On 8/31/2001 12:48:47 PM water line ok sewer line 20' from building ok will finish after tap is found sewer line req
PLM01-02999 Sprinkler (Final)8/30/20018/31/20018/31/2001 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 08/30/2001 at 16:36:04. Contact: ###-####.underground ok not certified 8/31/2001 1:21:49 PM