Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC14-00892 General Inspection8/31/20158/31/20158/31/2015 4:20:44 PM PASS
All townhomes in Bella Vista have been framed. WIP on the east 7 homes, whiles the 7 homes on the west are very near completion. Trash and materials have been recently cleaned. No vdischarges or spills observed. No corrections issued.
ESC15-00927 Site Preparation8/31/20158/31/20158/31/2015 2:49:07 PMPPASS
BMPs installed, permit sign posted. No excavation started. Approved for construction.
ESC15-00929 Site Preparation8/31/20158/31/20158/31/2015 2:11:48 PMPPASS
Inspection requested via web by Erby Gonzales


Permit signs posted in Park Place. BMPs installed include DI bags and concrete washout bin. Trash and materials for active projects are contained. Chain link fence installed around perimeter to control access and contain wind blown debris from construction activity. Approved.
ESC15-00964 Site Preparation8/31/20158/31/20158/31/2015 2:11:20 PMPPASS
Inspection requested via web by Erby Gonzales


Permit signs posted in Park Place. BMPs installed include DI bags and concrete washout bin. Trash and materials for active projects are contained. Chain link fence installed around perimeter to control access and contain wind blown debris from construction activity. Approved.
ESC15-00966 Site Preparation8/31/20158/31/20158/31/2015 2:10:38 PMPPASS
Inspection requested via web by Erby Gonzales

Permit signs posted in Park Place. BMPs installed include DI bags and concrete washout bin. Trash and materials for active project are contained. Chain link fence installed around perimeter to control access and contain wind blown debris from construction activity. Approved.
ESC13-00259 Aging Inspection8/31/20158/31/20158/31/2015 1:58:36 PM PEND
All construction in Tripplett townhome subdivision is complete. All temporary BMPs have been removed except for the two DI bags on Triplett.

Request to remove inlet bags issued in order to Final permit.
ESC13-01279 General Inspection8/31/20158/31/20158/31/2015 1:51:18 PM PART
WIP at south end of Lucky Harris sub. Trash contained, clearing limits are being respected and perimeter BMPs installed. DI bags installed on all inlet. Projects have permit signs posted.

1 correction:
- need to allow current washout to dry out and haul away. Install new washout for next round of homes. 5 new ones were just poured and washout was utilized..
ESC15-00954 Site Preparation8/31/20158/31/20158/31/2015 1:37:26 PMPPASS
Inspection requested via web by Erby Gonzales

Brighton Homes' SFHs in progress are currently in compliance. Permit sign posted, subdivision BMPs installed. Approved for excavation.
ESC14-00169 Aging Inspection8/31/20158/31/20158/31/2015 12:24:37 PM PASS
ESC13-00471 Aging Inspection8/31/20158/31/20158/31/2015 11:41:28 AM PASS
2 SFHs in progress at Tianna Park by Sunrise Homes. No trackout or discharges, inactive/complete areas have had DI bags removed. 1 bag installed on Spinnaker where work is. Workers keeping clean, no trash or litter issues.

Will request that gatorguard wattles in stand windows be removed. Approved.
ESC14-00588 General Inspection8/28/20158/31/20158/31/2015 11:13:02 AMAPASS
WIP on foundations and utility installations for apartment buildings in the District @ Parkcenter. No active dewatering at time of inspection. Irrigation ditch was rerouted from the former infiltration/holding pond (which is being drained and replaced per plans) and is flowing into Loggers Creek. There is no significant plume observed and water passes through silt fence barriers, check dames, undisturbed stream bank vegetation and straw wattle. I stated that the discharge should be monitored several times daily turbidity measurements taken when dewatering.

No trackout, construction entrance in operable condition. New wattles have been installed along the project frontage on Parkcenter inside chainlink fence. Fuel tank secondary containment is in good condtion; spill kit on site.

No corrections issued.
ESC14-00212 General Inspection8/31/20158/31/20158/31/2015 10:20:37 AM PEND
All construction complete. Residents have moved into Lusk Place for Fall semester. Large dumpster belongs to Vista Apartments.

Landscaping and hydroseeding is complete. Grass has started to grow well on the east and south of site. Area around Anniversary Inn culvert and DD3 outlet is completey stabile.

Request to McAlvain to remove DI bag on Lusk Street. RP-GC stated he will remove today. RP also stated that he will inform manager to warn students about litter. Lots of non-construction litter on Lusk street observed.
ESC39-00002 Aging Inspection8/31/20158/31/20158/31/2015 9:42:31 AM CANC
test case entry. not an active permit
ESC14-00653 Aging Inspection8/31/20158/31/20158/31/2015 9:13:01 AM PASS
ESC14-01139 General Inspection8/31/20158/31/20158/31/2015 8:42:50 AM PASS
WIP within storage yard. No sediment leaving site. No corrections issued.
ESC14-01138 General Inspection8/31/20158/31/20158/31/2015 8:42:42 AM PASS
WIP within storage yard. No sediment leaving site. No corrections issued.